Control descriptions 

 
 
-   

Temperature indicator light (A) 

 
-   

Adjustment thermostat 0°- 90°C (B) 

 
-   

Loaded circuit breaker (C) with voltage led 

 
-   

Water drain tap (D) only for models BMV/11-21-31 

 

 

 

 
 

Recommendations for use  

Before using the machine remove, if found, the special protective film. 
Unpleasant odours produced during the first minutes of operation are due to the presence of processing 
grease residues.  
On first use, heat the machine to the maximum temperature. 

 
 

Stailess steel double boiler lunch counters use 

Pour water (possibly decalcified) in the basin until a level of approximately 3 cm is reached, please notice 
that it is necessary to control the water level periodically, in order to avoid serious equipment damage. The 
equipment must be installed connecting the power cords to the proper sockets foreseen in the working 
environment where they must be placed. To turn the machine on, press the main switch -it will light up- and 
turn the thermostat knob to set the required temperature (al least 65°C); the red led will light up indicating 
that the resistance is working correctly. Once the required temperature has been reached, the led will turn off 
and it will turn back on when the temperature decreases enough (approximately 5° C) to justify resistance 
functions.

 

At the end of the day, turn the main switch off, leaving the temperature set. 

Only the models 

BMV11, BMV21

 and 

BMV31

 are equipped with an additional ½ 

tap that allows the water, 

whichis inside the lunch counters, to overflow. 

Warning:

 discharge the water only when it is completely cold. 

 

End of the day cleaning  

 

Remove the plug from the electrical socket at the end of the day. 

 

Accurately clean using neutral products. 

 

Clean external machine parts with a damp sponge when the machine is fully cooled. 

 

Do not use metallic pads and abrasive detergents. 

 

To avoid hazards caused by contact with high temperature parts, only access heating parts after 
maintenance operations have been completed.

 

 
 

Extended periods of disuse  

For extended periods of disuse, turn off the main wall switch, clean the machine and cover it with a cloth to 
protect if from dust. 
 

8

Summary of Contents for TAV11

Page 1: ...NOMARIA INOX STAINLESS STEEL DOUBLE BOILER LUNCH COUNTERS TABLES CHAUFFES A BAIN MARIE EN ACIER INOXYDABLE HEIZTISCHE AUS EDELSTAHL Manuale d uso e manutenzione Operation and maintenance manual Manuel...

Page 2: ...ioni sulla sicurezza 2 INFORMAZIONI SULL INSTALLAZIONE Imballo e disimballo Zona d installazione Collegamento elettrico 4 4 5 5 6 6 7 7 7 3 INFORMAZIONI SULL USO E LA PULIZIA Descrizione dei comandi C...

Page 3: ...on la macchina Conservare questo manuale in un luogo appropriato al fine di averlo sempre a portata di mano per la sua consultazione Per mettere in evidenza alcune parti del testo sono stati inseriti...

Page 4: ...are bacinelle G N fino ad h 150 o per altre tipologie di contenitori adatti ad un uso alimentare Solo i modelli BMV11 BMV21 e BMV31 sono dotati di un rubinetto per lo scarico dell acqua esso collocato...

Page 5: ...ciamento e la messa in opera della macchina devono essere eseguiti solo da personale tecnico specializzato Verificare che le caratteristiche dell impianto dove va installata la macchina corrispondano...

Page 6: ...eve essere eseguita tenendo conto anche delle leggi vigenti in materia di sicurezza sul lavoro Tabella Condizioni ambientali Descrizioni Valori Temperatura di funzionamento 0 35 C 32 95 F Temperatura...

Page 7: ...ottenere non meno di 65 C in questo modo si illuminer la spia rossa che ha la funzione di segnalare il buon funzinamento della resistenza Questa una volta raggiunta la temperatura desiderata si spegne...

Page 8: ...on riscalda Interruttore generale disinserito Inserire l interruttore generale Mancanza di tensione sulla linea d alimentazione Contattare Servizio Assistenza del vostro Rivenditore Resistenza o termo...

Page 9: ...mensions Safety information 2 INSTALLATION INFORMATION Packaging and unpacking Installation area Electrical connections 4 4 5 5 6 6 7 7 7 3 USE AND CLEANING INFORMATION Control descriptions Recommenda...

Page 10: ...he hands of all the operators who interact with the machine Keep this manual in a suitable place always within reach for consultation The following symbols are included to better stress some passages...

Page 11: ...150 or other types of food containers Only the BMV11 BMV21 and the BMV31 models are provided with a tap for the water drain the tap is located on the off sides and it ends with a sluice gate Technica...

Page 12: ...o the elements Machine connections and start up must only be performed by qualified technicians Make sure that the system specifications of the room where the machine is installed correspond to the in...

Page 13: ...ust also be performed in consideration of the work safety laws in force Room conditions table Descriptions Values Working temperature 0 35 C 32 95 F Storage temperature 15 to 65 C from 6 8 to 149 F Re...

Page 14: ...rmostat knob to set the required temperature al least 65 C the red led will light up indicating that the resistance is working correctly Once the required temperature has been reached the led will tur...

Page 15: ...ons Problem Cause Solution The machine does not heat Main switch off Turn on main switch No voltage on the power supply Contact your dealer s service centre Resistance or thermostat broken Contact you...

Page 16: ...s curit 2 INFORMATIONS SUR L INSTALLATION Emballage et d ballage Zone d installation Branchement lectrique 4 4 5 5 6 6 7 7 7 3 INFORMATIONS SUR L UTILISATION ET LE NETTOYAGE Description des commandes...

Page 17: ...teragissent avec la machine Conserver ce manuel dans un endroit appropri afin de l avoir toujours la port e de la main pour sa consultation Pour mettre en vidence certaines parties du texte les symbol...

Page 18: ...150 ou pour d autres typologies de r cipients indiqu s pour une utilisation alimentaire Seulement les mod les BMV11 BMV21 et BMV31 ont en dotation un robinetpuor d charger l eau le robinet se trouve s...

Page 19: ...se en service de la machine doivent tre effectu s uniquement par le personnel technique sp cialis V rifier que les caract ristiques de l installation o doit tre install e la machine correspondent aux...

Page 20: ...nstallation doit tre effectu e en tenant galement compte des lois en vigueur en mati re de s curit sur le travail Tableau Conditions d environnement Descriptions Valeurs Temp rature de fonctionnement...

Page 21: ...r au moins 65 C de cette fa on le t moin rouge s allumera qui a pour fonction de signaler le bon fonctionnement de la r sistance Celle ci une fois que la temp rature souhait e aura t atteinte s teindr...

Page 22: ...ffe pas Interrupteur g n ral d clench Enclencher l interrupteur g n ral Manque de tension sur la ligne d alimentation Contacter le service Assistance de votre Revendeur La r sistance ou le thermostat...

Page 23: ...t 2 INFORMATIONEN ZUR INSTALLATION Verpackung und Auspacken Installationsbereich Elektrischer Anschluss 4 4 5 5 6 6 7 7 7 3 INFORMATIONEN ZUR BEDIENUNG UND REINIGUNG Beschreibung der Bedienungselement...

Page 24: ...ine interagieren Bewahren Sie dieses Handbuch an einem geeigneten Ort auf sodass dieses im Bedarfsfall stets sofort greifbar ist Zur besonderen Hervorhebung einiger Textstellen wurden folgende Symbole...

Page 25: ...Schalen f r bis zu 150 von Hohe oder f r andere Lebensmittel geeignete Beh lter ausgelegt Nur die Modelle BMV11 BMV21 und BMV31 verf gen ber ein Wasserauslaufhahn er befindet sich an einer Seite und i...

Page 26: ...Agenzienaus AnschlussundInbetriebnahmederMaschinesindnurvontechnischemFachpersonaldurchzuf hren StellenSiesicher dassdieKenndatenderAnlageamAufstellungsortderMaschinedenaufdemTypenschildeingepr gten W...

Page 27: ...n In jedem Fall ist die Installation auch unter Beachtung der geltenden gesetzlichen Vorschriften zur Arbeitssicherheit durchzuf hren Tabelle mit Umgebungsbedingungen Beschreibungen Werte Betriebstemp...

Page 28: ...s 65 C Auf diese Weise leuchtet die rote Kontroll Lampe auf um den st rungsfreien Betrieb des Widerstands anzuzeigen Nach dem Erreichen der gew nschten Temperatur geht die Lampe aus und leuchtet jedes...

Page 29: ...inschalten Spannung auf der Versorgungsleitung fehlt Nehmen Sie Kontakt mit dem Technischen Kundendienst Ihres H ndlers auf Heizwiderstand oder Thermostat nicht funktionst chtig Nehmen Sie Kontakt mit...

Page 30: ...interruttore Circuit breaker switch E SL0629 Pressacavo dado Wire clip nut F SL0628 Cavo di alimentazione Power cord G SL0643 Piedini Feet H SL0794 Vasca 1 1 H 160 Container 1 1 H 160 I SL0721 Rubine...

Page 31: ......

Reviews: