background image

BAYKAN ISI SIST.SAN.TIC.AS.

1

CONTENTS

 I         WARNINGS

PAGE.    2

II       TECHNICAL SPECIFICATIONS

PAGE    3

II. 1    TABLE OF TECHNICAL DATA

II. 2    EXTERIOR DIMENSIONS

II. 3    OPERATION DIAGRAM

II. 4    MAIN COMPONENTS OF THE WALL HUNG BOILER

II. 5    GRAPH OF FLOW AND HIGHEST PUMPING POINT

II. 6    ELECTRICITY DIAGRAM

III     SETTING UP

PAGE 8

III. 1   THE PLACEMENT FOR INSTALLING

III. 2   MOUNTING THE WALL HUNG BOILER

III. 3  CONNECTING THE TERMINALS OF DISCHARGE

IV     OPERATING

PAGE 14

IV.  1   WARNINGS CONCERNING THE USER

IV.  2   TURNING THE WALL HUNG BOILER ON, ITS FUNCTIONS AND TURNING IT OFF

IV.  3   OPERATION OF THE WALL HUNG BOILER BY MEANS OF THE EXTERNAL THERMOSTAT

IV.  4   WARNINGS OF THE WALL HUNG BOILERS IN EXTRAORDINARY SITUATIONS

V      ADJUSTMENTS AND MAINTENANCE

PAGE 22

V.    1     ADJUSTMENTS

V.   2     REPLACING THE TYPE OF GAS BEING USED

V.    3     OTHER ADJUSTMENTS

V.   4     MAINTENANCE

Summary of Contents for 24kW Baykan Starplus

Page 1: ... moon 28kW Baykan moon 24kW Baykan sun 28kW Baykan sun 24 kW Bithermic Type C Hermetic Wall Hung Boiler 24 kW Baykan sun Our highly esteemed customers We would like to thank you for your thrust in our company Baykan and your decision for purchasing products of Baykan Our devices have been manufactured with the latest technology and they offer you the best comfort of use and heating 1 st Edition Ma...

Page 2: ...telephone or other such device that may cause sparks immediately open doors and Windows turn the gas tap off finally demand the assistance and service of qualified personnel to correct the factors which caused the said leakage It is recommended that gas leak detection devices should be used at proper locations in areas where the wall hung boiler is installed If the wall hung boiler is not used for...

Page 3: ...ase If everything goes right LED number 2 will glow which means there is flame if the boiler does not ignite LED number 8 will flash this indicates that the ignition has not been performed To remedy this situation and start the ignition cycle again turn the A selector to OFF R RESET position momentarily and rotate it to SUMMER function again Caution Before Wall hung boiler indicates blocked positi...

Page 4: ...l be displayed on the screen the number following the letter E will specify the type of failure that arises In order to remedy this situation turn the A selector to OFF R position momentarily and turn it into SUMMER mode again CAUTION Before the wall hung boiler specifies the blocking condition the ignition circulation will be repeated three times automatically ADJUSTING THE TEMPERATURE OF WATER T...

Page 5: ...t the desired mode among SUMMER or WINTER modes the selected mode will be displayed with the corresponding symbols on the screen If WINTER mode is selected the boiler will automatically turn on whenever there is need for the boiler to warm or whenever there is need for tap water If the SUMMER mode has been selected the boiler will only turn on when there is need for hot tap water Select SUMMER mod...

Page 6: ... used for longer periods the gas tap must be turned off and the electricity that leads to wall hung boiler must be cut off by the bipolar circuit breaker on the device especially in order to prevent the damages caused by freezing during winter period both the water in the heating system and the tap water should be discharged The water in the heating system may cause evacuation if antifreeze mixtur...

Page 7: ... pressing the E marked reset button in the version with display and by pressing A in the version with switch If the problem still exists there is need for the assistance of authorized technical service E 03 or LED 30 THE CODE DISPLAYED IN CASE OF THE HEATING THERMOSTAT NEEDING TO BE SERVICED DUE TO AGE This sign is displayed when the heating thermostat runs improperly the wall hung boiler is block...

Page 8: ...40 THE CODE DISPLAYED CONCERNING THE MALFUNCTIONS OF THE MODULATOR It appears when there is a case of malfunctioning of modulator the wall hung boiler is not blocked and keeps working In this case the connections of gas valves with the modulator must be checked If the mentioned condition carries on you must contact an authorized dealer E 07 or LED 80 LED 60 THE CODE DISPLAYED CONCERNING THE MALFUN...

Page 9: ...the wall Materials which may obstruct the air flow should not be placed in front of the orifices These orifices must be preserved with unique grilled covers and no materials that may obstruct the air flow must be put in front of it The air orifice must be on the wall or above the window As shown in the figure The orifice below must be close to the floor and the orifice above must be close to the c...

Page 10: ...cers and they are not limited by any regulations regarding the area of their installing The said devices can not in any case be installed in positions entertaining the risk of fire such as barns cellars garages unoccupied areas in buildings It is forbidden Since the Hermetic devices supply the air for combustion from outdoor and not interior areas there is no obligation for an air orifice There is...

Page 11: ...e the manufacturer of the wall hung boiler shall not be liable for the cases that arise due to the intermeddling of the safety valve Place a valve to the inlet of each of water and gas pipe lines Ensure that the pressure of domestic water is 1 6 bars If the water pressure is higher than 6 bars use pressure set up valve A dirt collector must be connected to the water entries fiek 6 Perform the foll...

Page 12: ...ble comply with the signs on the main input connector Please connect the blue cable to the connector marked with N Connect the brown cable to the connector marked with letter L Connect the yellow green cable to the connector signed with grounding sign While changing the cable use the specified cables H05VVF H05 VVH2 F 2 4 ROOM THERMOSTAT CONNECTION Have the room thermostat connection of the device...

Page 13: ... evacuated Caution While operating always compare the value of the central heating system displayed on screen to the value on the label Res 8 4 WASTE GAS FLUE DUCT CONNECTIONS The connections to be made with the waste gas pipes and if available the discharge pipes on the walls must be performed in conformity with the technical specifications of Gas Distribution Company In the buildings where there...

Page 14: ...nnel should be fixed to the inlet of fume pipe or duct and it should not decline inside The length of fume channel must be larger than the section of the connection point of device to the discharge If the duct or fume pipe has a smaller diameter than that of the fume channel then a tapered sleeve opposite to the connection point must be used The fume channel should have no cutting apparatus such a...

Page 15: ...meters FOR DEVICES TYPE C closed chamber The suitable waste gas discharge kits recommended by the manufacturer must be used Some examples concerning the installation of discharge kits have been given It is vital that the specified maximum distances concerning these must be observed see the table on page 3 It should also be predicted that each bracket placed on the surface will cause the maximum le...

Page 16: ...ength must be 1meter max and single bracket must be used The diameter of duct pipe must be 130mm for 24kW devices 140mm for 28 32 kW devices Waste gas pipe must be connected to the duct with a little slope Caution Duct channel must be cleaned once a year HERMET C WALL HUNG BOILERS The flue kit provided with the device must be installed properly and you must ensure that it does not leak The Duct ki...

Page 17: ...t kiti and wall hung boiler outlet BAYKAN 24KW BAYKAN 28KW BAYKAN 32KW DIAPHRAGMØ 37 41 44 Table of waste gas capacity losses for concentric and parallel waste gas kit parts Table of fume capacity loss for components of concentric and parallel pipes discharge kit COMPONENT P Pa Equivalent duct lenght Terminal Pipe L 990 25 2 8 Insertion L 1000 M F 6 1 Vertical flanged connection M 15 Bracket 90 M ...

Page 18: ...BAYKAN ISI SIST SAN TIC AS 17 2 1 Fig 10 1 WASTE GAS KIT 2 DIAPHRAGM ...

Page 19: ... 13 8 14 2 16 6 18 3 13 8 Domestic hot water production t 30 ºC l min 11 5 12 13 8 15 3 11 7 Max pressure on DHW system Bar 6 Min pressure on DHW system Bar 0 8 Domestic hot water temperature Min max C 30 60 ELECTRICAL CIRCUIT Power supply voltage frequency V Hz 230 50 Electrical power W 104 104 152 152 152 152 Grade of protection IP X4D DIMENSIONS AND CONNECTIONS Width Mm 400 Height Mm 700 Depth ...

Page 20: ...BAYKAN ISI SIST SAN TIC AS 4 2 DIMENSIONS Fig 1 HERMETIC WALL HUNG BOILER 330 400 700 WALL HUNG BOILER WITH FLUE DUCT 700 200 400 208 330 3 OPERATING DIAGRAM ...

Page 21: ... Main exchanger 2 Boiler 3 Gas Valve 4 Motorized 3 way valve 5 Safety Valve 6 Filling Valve 7 Domestic Water Flow sensor 8 Plate Exchanger 9 Pump 10 Expansion Tank BI TERMIC MODEL 24 kW Baykan Star 1 Main Exchanger 2 Boiler 3 Gas Valve 4 5 Safety valve 6 Filling Valve 7 Domestic Water flow sensor 8 9 Pump 10 Expansion Tank 4 MAIN COMPONENTS OF WALL HUNG BOILER ...

Page 22: ...WAY VALVE 7 TEMPERATURE OF CENTRAL HEATING WATER ISI SENSOR NTC 8 SAFETY VALVE 9 DOMESTIC WATER HEAT SENSOR NTC 10 DOMESTIC WATER FLOW SENSOR 11 PRESSURE SAFETY SWITCH TRANSDUCER 12 CIRCULATION PUMP 13 GAS VALVE 14 EXPANSION TANK 15 BOILER 16 GROUND ELEKTRODE 17 IGNITION ELECTRODE 18 FAN 19 WASTE GAS SAFETY THERMOSTAT 20 WASTE GAS CHAMBER 21 BITHERMIC EXCHANGER 22 DOMESTIC WATER HEAT SENSOR 5 PERF...

Page 23: ...BAYKAN ISI SIST SAN TIC AS 7 6 THE DIAGRAM OF THE ELECTRONIC CARD fiek 5 ...

Page 24: ...ies which have not been supplied by the manufacturer company The mounting and installing works must be provided by the authorized personnel and technical service staff Comply with the warnings operating and maintenance instructions specified in the manual In case of a failure or malfunction turn your wall hung boiler off shut the gas flow and never attemp to repair it on your own Before cleaning y...

Page 25: ...ngers and material damages on the device Hand Symbols mean important warnings Conformity with International Directives and Regulations Your device is certified by Turkish Standarts Institute TSI Certificate Number Your device is CE certified CE Certificate Number The device is in conformity with the directive numbered 92 42 EEC on Liquid and Gas burning devices The device is in conformity with the...

Page 26: ...1 THE PLACEMENT FOR INSTALLING III 2 MOUNTING THE WALL HUNG BOILER III 3 CONNECTING THE TERMINALS OF DISCHARGE IV OPERATING PAGE 14 IV 1 WARNINGS CONCERNING THE USER IV 2 TURNING THE WALL HUNG BOILER ON ITS FUNCTIONS AND TURNING IT OFF IV 3 OPERATION OF THE WALL HUNG BOILER BY MEANS OF THE EXTERNAL THERMOSTAT IV 4 WARNINGS OF THE WALL HUNG BOILERS IN EXTRAORDINARY SITUATIONS V ADJUSTMENTS AND MAIN...

Reviews: