2.2

Transportation and Storage

1) The heat pump MUST be transported and stored VERTICALLY!

2) The heat pump MUST be transported and stored uprightly on a pallet with good package.

3)  Should the heat pump be laid down, please wait at least 12 hours before switching it on

3.

Technical data

3.1

Technical Table

GSR11-PL

GSR13-PL

GSR18-PL

GSR26-PL

Air 24°C

/Water 27 °C

[1]

Heating Capacity

W

11000

13500

18000

26000

BTU

37510

46035

61380

88660

Heating Input Power

W

1925

2180

2610

4750

Heating Running Current

A

9.78

10.43

12.5

8.39

COP

.10

5.7

5.3

5.47

Max. Current

A

16

18

24

14

Power Supply

V/Ph/Hz

220V/1Ph/50Hz

220V/1Ph/50Hz

220V/1Ph/50Hz

380V/3/50Hz

Setting temp. Range

15°C~40°C

15°C~40°C

15°C~40°C

15°C~40°C

Running Temp. Range

-5°C~43°C

-5°C~43°C

-5°C~43°C

-5°C~43°C

Refrigerent Type

R410a

R410a

R410a

R410a

Condenser

Titanium in PVC

Titanium in PVC

Titanium in PVC

Titanium in PVC

Evaporator

Hydrophilic

aluminium/φ9.52

innergroove tube

Hydrophilic

aluminium/φ9.52

innergroove tube

Hydrophilic

aluminium/φ9.52

innergroove tube

Hydrophilic

aluminium/φ9.52

innergroove tube

Fan motor

Power Input

W

80

80

140

320

Fan Speed

RPM

900

900

800

800

Capillary or Expansion Valve

Capillary

Capillary

Capillary

Capillary

Controller

LCD

LCD

LCD

LCD

Water Inlet/Outlst Dimension

"

1.5"

1.5"

1.5"

1.5"

Hydraulic Connection

mm

PVC 50

PVC 50

PVC 50

PVC 50

Water Flow Volume

m³/h

5

5.5

6

8

Sound Pressure Level at 1M/4M/10M [2]

kpa

52/40/32

52/40/32

52/40/32

55/44/34

Dimension

L*W*H

mm

1012*306*613

1012*306*613

1116*425*686

752*691*959

Packing Size

L*W*H

mm

1135*390*750

1135*390*750

1250*505*825

840*750*1100

Weight

Net Weight

kg

68

105

115

124

Gross Weight

78

120

130

146

1

Ambient air temperature 24°C(DB)/19°C(WB), inlet water temperature°C27

2

Noise from 1meter,4 meters or 10 meters (in DBA) (As in the directives EN ISO 3741 & EN ISO 354...)

Summary of Contents for GSR-11-PL

Page 1: ...INSTALLATION AND USER MANUAL EN 50 70 90 115 125 150 POOL HEAT PUMP GSR 11 PL GSR 13 PL GSR 18 PL GSR 26 PL ...

Page 2: ...Panel 14 6 1 ON OFF 14 6 2 Working Modes 14 6 3 Time Setting 15 6 4 Water Temperature Setting 15 6 5 Working information 15 6 6 Water flow detection 16 7 Internal Parameters 16 7 1 Controller State Table 16 8 Maintenance and Trouble Shooting 17 9 Manometer Instruction 17 CONTENT 1 ATTENTION Before installing mounting the heat pump please read this user manual carefully Otherwise heat pump may be d...

Page 3: ... refrigerant within the EVAPORATOR coil absorbs the heat from the outside air becomes a gas The warm gas in the coil passes through the COMPRESSOR concentrating and increasing the heat to form a very hot gas which then passes to the CONDENSER water heat exchanger It is here that the heat exchange occurs as the hot gas gives off heat to the cool swimming pool water circulating through the coil The ...

Page 4: ... and the Wiring diagram provided in this manual 2 Connecting the heat pump to a ground wire is necessary in order to prevent electrical shock caused by an unexpected short circuit inside the unit 3 Please install the electrical protection devices according to the local regulations 4 The heat pump must be installed on reliable base or supporting framework 5 If the heat pump is installed on the floo...

Page 5: ...ndenser Titanium in PVC Titanium in PVC Titanium in PVC Titanium in PVC Evaporator Hydrophilic aluminium φ9 52 innergroove tube Hydrophilic aluminium φ9 52 innergroove tube Hydrophilic aluminium φ9 52 innergroove tube Hydrophilic aluminium φ9 52 innergroove tube Fan motor Power Input W 80 80 140 320 Fan Speed RPM 900 900 800 800 Capillary or Expansion Valve Capillary Capillary Capillary Capillary ...

Page 6: ...5 4 Dimensions GSR11 PL GSR13 PL GSR18 PL GSR 11 PL GSR 13 PL GSR 18 PL A 372 422 422 B 392 452 452 C 650 640 640 D 628 754 754 E 1006 1026 1026 F 260 300 355 G 145 135 122 H 344 415 415 ...

Page 7: ...6 GSR26 PL GSR 26 PL A 960 B 752 C 691 D 765 E 460 F 122 G 450 ...

Page 8: ... accompanied with oil Inflammable gas corrosive components e g Sulfur compound or high frequency equipment 7 The unit must be installed on reliable base or framework Weight capacity of framework should be 3 times of the body weight and safeguard measures should be taken to avoid malfunction of fastenings 8 The unit should not be installed at sites with typhoon earthquake hazards Midair installatio...

Page 9: ...when the flow of the pool pump exceeds the authorized flow through the heat exchanger of the heat pump with 20 5 2 Pool Connection Diagram With the by pass set correctly best performance of the pool heat pump will be made Please see the right diagram for the connection SETTING Valve 1 close slightly Valve 2 open half way Valve 3 open completely ...

Page 10: ...the valve which connected to water outlet to avoid frost crack 3 If the unit is under off season should cut off power and take the protection cover outside of unit when necessary 4 Before restart the unit which has drained out all the water inside the user is advised to reinstall the unit and adjust program further more need complete check of the system 5 4 NOTS for Anti Freezing in Winter The fil...

Page 11: ...ction to a general power supply with full earth and neutral or neutral earth systems 3 The power supply cable must be connected to a circuit breaker with at least a 3mm breaking gap Incoming supply must be 220 240V 1 50Hz via a distribution board with fuses 4 If an insulation test is to be carried out in the building please make sure to disconnect the heat pump 5 The communication wire must be STP...

Page 12: ...11 GSR11 PL GSR13 PL 5 6 Electric Circuit Drawing ...

Page 13: ...12 GSR18 PL ...

Page 14: ...13 GSR26 PL ...

Page 15: ... machine comes to a complete hold Button serves to change the working mode By pressing this button the icon corresponding to the selected mode will appear Automatic heating and cooling The heat pump will maintain the water temperature at the desired value 1 C Heating only heating Heats the water up to the desired value 1 C Cooling mode only cooling Cools the water down to the desired value 1 C 6 1...

Page 16: ...e fan Third indicate the compressor During the start time delay the corresponding symbol will blink Symbol indicates that the machine is defrosting Symbol indicates that the keyboard is locked To lock or unlock the keyboard press and simultaneously during several seconds 6 3 Time Setting 6 4 Water Temperature Setting 6 5 Working Information Set hours with or Press one time button to confirm The he...

Page 17: ...tration pump is working Check by pass setting EE7 Memory problem Change PCB EE8 Communication error Check electrical connection between controller and electronic card inside the machine PP1 Probe error Water in Check probe connection PP3 PP10 Probe error evap PP4 PP11 Probe error comp in PP5 Probe error ambiance PP6 PP8 Too much difference between water in and water out Check by pass setting PP7 D...

Page 18: ...ter Before stopping the heat pump for long time drain out all water in the pipes and shut off the power supply and put it into a shield Full inspection of the system is required before next operation All protective settings in the unit have been set before ex factory Users must not adjust it when the heat pump unit is in use Users should call the installer or the seller every time when there is an...