1. The heat pump unit has auto antifreeze program. When the unit is working normally, there will not be 

freezing.

2. When the ambient temperature is minus, and the unit stops for over 3 hour, or the unit stops long term 

when power off, the user is advised to drain all the water inside popes through the valve which connected to 

water outlet to avoid frost crack.

3. If the unit is under off season, should cut off power and take the protection cover outside of unit when 

necessary.

4. Before restart the unit which has drained out all the water inside, the user is advised to reinstall the unit 

and adjust program, further more need complete check of the system.

5.4

NOTS for Anti-Freezing in Winter

The filter connected with pipes should be cleaned regularly to make sure the water inside systems clean,

Summary of Contents for GSR-11-PL

Page 1: ...INSTALLATION AND USER MANUAL EN 50 70 90 115 125 150 POOL HEAT PUMP GSR 11 PL GSR 13 PL GSR 18 PL GSR 26 PL ...

Page 2: ...Panel 14 6 1 ON OFF 14 6 2 Working Modes 14 6 3 Time Setting 15 6 4 Water Temperature Setting 15 6 5 Working information 15 6 6 Water flow detection 16 7 Internal Parameters 16 7 1 Controller State Table 16 8 Maintenance and Trouble Shooting 17 9 Manometer Instruction 17 CONTENT 1 ATTENTION Before installing mounting the heat pump please read this user manual carefully Otherwise heat pump may be d...

Page 3: ... refrigerant within the EVAPORATOR coil absorbs the heat from the outside air becomes a gas The warm gas in the coil passes through the COMPRESSOR concentrating and increasing the heat to form a very hot gas which then passes to the CONDENSER water heat exchanger It is here that the heat exchange occurs as the hot gas gives off heat to the cool swimming pool water circulating through the coil The ...

Page 4: ... and the Wiring diagram provided in this manual 2 Connecting the heat pump to a ground wire is necessary in order to prevent electrical shock caused by an unexpected short circuit inside the unit 3 Please install the electrical protection devices according to the local regulations 4 The heat pump must be installed on reliable base or supporting framework 5 If the heat pump is installed on the floo...

Page 5: ...ndenser Titanium in PVC Titanium in PVC Titanium in PVC Titanium in PVC Evaporator Hydrophilic aluminium φ9 52 innergroove tube Hydrophilic aluminium φ9 52 innergroove tube Hydrophilic aluminium φ9 52 innergroove tube Hydrophilic aluminium φ9 52 innergroove tube Fan motor Power Input W 80 80 140 320 Fan Speed RPM 900 900 800 800 Capillary or Expansion Valve Capillary Capillary Capillary Capillary ...

Page 6: ...5 4 Dimensions GSR11 PL GSR13 PL GSR18 PL GSR 11 PL GSR 13 PL GSR 18 PL A 372 422 422 B 392 452 452 C 650 640 640 D 628 754 754 E 1006 1026 1026 F 260 300 355 G 145 135 122 H 344 415 415 ...

Page 7: ...6 GSR26 PL GSR 26 PL A 960 B 752 C 691 D 765 E 460 F 122 G 450 ...

Page 8: ... accompanied with oil Inflammable gas corrosive components e g Sulfur compound or high frequency equipment 7 The unit must be installed on reliable base or framework Weight capacity of framework should be 3 times of the body weight and safeguard measures should be taken to avoid malfunction of fastenings 8 The unit should not be installed at sites with typhoon earthquake hazards Midair installatio...

Page 9: ...when the flow of the pool pump exceeds the authorized flow through the heat exchanger of the heat pump with 20 5 2 Pool Connection Diagram With the by pass set correctly best performance of the pool heat pump will be made Please see the right diagram for the connection SETTING Valve 1 close slightly Valve 2 open half way Valve 3 open completely ...

Page 10: ...the valve which connected to water outlet to avoid frost crack 3 If the unit is under off season should cut off power and take the protection cover outside of unit when necessary 4 Before restart the unit which has drained out all the water inside the user is advised to reinstall the unit and adjust program further more need complete check of the system 5 4 NOTS for Anti Freezing in Winter The fil...

Page 11: ...ction to a general power supply with full earth and neutral or neutral earth systems 3 The power supply cable must be connected to a circuit breaker with at least a 3mm breaking gap Incoming supply must be 220 240V 1 50Hz via a distribution board with fuses 4 If an insulation test is to be carried out in the building please make sure to disconnect the heat pump 5 The communication wire must be STP...

Page 12: ...11 GSR11 PL GSR13 PL 5 6 Electric Circuit Drawing ...

Page 13: ...12 GSR18 PL ...

Page 14: ...13 GSR26 PL ...

Page 15: ... machine comes to a complete hold Button serves to change the working mode By pressing this button the icon corresponding to the selected mode will appear Automatic heating and cooling The heat pump will maintain the water temperature at the desired value 1 C Heating only heating Heats the water up to the desired value 1 C Cooling mode only cooling Cools the water down to the desired value 1 C 6 1...

Page 16: ...e fan Third indicate the compressor During the start time delay the corresponding symbol will blink Symbol indicates that the machine is defrosting Symbol indicates that the keyboard is locked To lock or unlock the keyboard press and simultaneously during several seconds 6 3 Time Setting 6 4 Water Temperature Setting 6 5 Working Information Set hours with or Press one time button to confirm The he...

Page 17: ...tration pump is working Check by pass setting EE7 Memory problem Change PCB EE8 Communication error Check electrical connection between controller and electronic card inside the machine PP1 Probe error Water in Check probe connection PP3 PP10 Probe error evap PP4 PP11 Probe error comp in PP5 Probe error ambiance PP6 PP8 Too much difference between water in and water out Check by pass setting PP7 D...

Page 18: ...ter Before stopping the heat pump for long time drain out all water in the pipes and shut off the power supply and put it into a shield Full inspection of the system is required before next operation All protective settings in the unit have been set before ex factory Users must not adjust it when the heat pump unit is in use Users should call the installer or the seller every time when there is an...

Page 19: ...iklik hakkı saklıdır Gassero Isı Teknolojileri Sanayi Limited Şirketi İstanbul Endüstri ve Ticaret Serbest Bölgesi 4 Sokak No 8 34957 Tuzla Istanbul TÜRKİYE Telefon 90 216 394 09 85 86 87 Faks 90 216 394 24 91 www gassero com ...