background image

5

4

GENERAL ASSEMBLY

Connecting & Disconnecting to Gas Source

Familiarise yourself with the general information and 
safety guidelines located at the front of this manual.

Check:

1.  The cylinder is filled. A sloshing sound will be heard 

when shaken.

2.  The control knob is in the ‘OFF’ position.

Connecting

1.  Ensure cylinder valve is in its full off position.
2.  Check for any damage to either the cylinder 

connection or the hose. NEVER attempt to use 
damaged equipment.

IMPORTANT: Before connecting and 
disconnecting appliance to gas source, 
make sure control knob is in ‘OFF’ position.
CAUTION: When the appliance is not in use, 
the gas must be turned off at the cylinder.

PARTS LIST

3.  When connecting the hose to the cylinder tighten the 

nut to a positive stop by hand.

4.  Open cylinder valve fully. If a leak can be heard at 

either end of the hose, turn cylinder off and tighten 
joint. Wait 5 minutes before re-testing and use a 
soapy water solution to check the joint. If bubbles 
appear the connection will need to be re-tightened.

  Refer to page 6 for more detailed instructions on 

connecting the appliance to the cylinder.

Disconnecting

1.  Ensure the burner control is in the ‘OFF’ position.
2.  Ensure cylinder valve is in the full off position.

For storage and cylinder exchange, disconnect hose 
at the cylinder only, DO NOT disconnect hose from 
appliance.

A

B

C

D

E

Lava Rocks

Body

1PC

Door

1PC

Cover

1PC

Battery (AAA)

1PC

E

A

B

C

D

Summary of Contents for Keystone GM142-140

Page 1: ...liquids in the vicinity of this or any other appliance An LPG Cylinder not connected for use shall not be stored in the vicinity of this or any other appliance Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment CARBON MONOXIDE HAZ...

Page 2: ... appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water 12 DO NOT operate this appliance unless it is fully assembled 13 DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION 14 Before use Remove any debris from within t...

Page 3: ...e pilot goes out the unit will automatically turn off REGULATOR SAFETY FEATURE All QCC regulators the part that attaches to the gas cylinder to regulate the flow of gas have a safety feature included that restricts gas flow in the event of a gas leak You can inadvertently activate this safety feature without having a gas leak This typically occurs when you turn on the gas using the appliance contr...

Page 4: ...t in use the gas must be turned off at the cylinder PARTS LIST 3 When connecting the hose to the cylinder tighten the nut to a positive stop by hand 4 Open cylinder valve fully If a leak can be heard at either end of the hose turn cylinder off and tighten joint Wait 5 minutes before re testing and use a soapy water solution to check the joint If bubbles appear the connection will need to be re tig...

Page 5: ...Ignition pin wire 1 5 Burner plate 1 6 Fire table 1 7 Door 1 8 Burner ring 1 9 Nozzle 1 1 2 3 4 5 6 7 8 9 10 11 12 16 14 15 13 17 No Part Name Qty 10 Metal hose 1 11 Safety valve 1 12 Hose and regulator 1 13 Control knob 1 14 Ignitor 1 15 Foot 4 16 Wing screw with nut 1 17 Metal stand 1 ...

Page 6: ...r Tighten the nut to a positive stop by hand STEP 12 Turn on the gas cylinder ensuring that the control knob on the outdoor heater is turned OFF at this point DO NOT ATTEMPT TO LIGHT THE HEATER STEP 13 Use a solution of soapy water dishwashing liquid and water is fine Brush it on or use a spray bottle as shown in the drawing Ensure the connections have a good coating STEP 14a If the connection is l...

Page 7: ...sure proper operation STEP 14b Tighten the connections using a crescent then repeat steps 12 13 STEP 14c The connection is gas tight when no bubbles grow around the gas connection d and as ave a STEP 14a If the connection is leaking bubbles will start to grow in the soapy solution If this happens shut off the gas supply at the cylinder epeat STEP 14c The connection is gas tight when no bubbles gro...

Page 8: ...freezing temperatures Keep the fire table area clear and free from combustible materials gasoline and other flammable vapors and liquids If the fire table is not in use it must be covered to protect from weather or other adverse elements Never use a vacuum cleaner on the lava rocks Installation and repair should be done by a qualified service person The fire table should be inspected at least annu...

Page 9: ...y Regulator hose is pinched Check the regulator hose for bends or kinks Sudden drop in gas flow No gas flow Check if gas cylinder is empty If yes replace Excess flow safety valve has been activated Turn the control knob to OFF Close the gas cylinder valve and disconnect the regulator from the cylinder Turn the control knob to HIGH Wait 1 minute Turner the control knob to OFF Reconnect regulator to...

Page 10: ...10 This page has been intentionally left blank ...

Page 11: ...11 This page has been intentionally left blank ...

Page 12: ...12 ...