background image

3

2

7.  The hose assembly should be properly located out 

of pathways where people may trip over it. The hose 
must be protected from contact with hot or sharp 
surfaces both during use and while in storage. The 
hose assembly should be visually inspected prior 
to each use of the appliance. If excessive abrasion 
or wear is evident, or the hose is cut, it must be 
replaced prior to operating the appliance. The 
replacement hose assembly may be obtained from 
the distributor.

8. 

DO NOT use any pressure regulator or hose 
assembly other than those supplied with the 
appliance. Replacement pressure regulator and hose 
assembly must be those specified. Replacement 
parts may be obtained from the distributor.

9.  Installation and use of this appliance must conform 

with New Zealand Standard 5601 “Gas Installations”.

10. This appliance is designed to operate with a standard 

9Kg LPG cylinder to DOT 4BA-240 with Approved 
Cylinder Connection.

11.  The valve outlet must be maintained in good 

condition. When the cylinder is not in use, be sure 
to cover it with a dust cap. A leak test should be 
performed with soapy water whenever connecting a 
new cylinder. 

NEVER use a flame to test for leaks.

12. The LPG cylinder must be turned off whenever the 

appliance is not in use. When the appliance is to be 
stored indoors, the LPG cylinder and the appliance 
must be disconnected and the cylinder stored in 
accordance with LPG Dangerous Goods Regulations.

13. Store the appliance upright in an area sheltered 

away from weather conditions. The use of a cover is 
recommended.

14. The appliance has been designed with several safety 

features which include a tip over switch and a flame 
safeguard system which means if the pilot goes out 
the unit will automatically turn off.

REGULATOR SAFETY FEATURE

All QCC regulators (the part that attaches to the gas 
cylinder to regulate the flow of gas) have a safety feature 
included that restricts gas flow in the event of a gas leak. 
You can inadvertently activate this safety feature without 
having a gas leak. This typically occurs when you turn 
on the gas using the appliance control knob before you 
turn on the gas cylinder valve. If the gas regulator safety 
feature activates, the appliance will operate with reduced 
output as gas flow is restricted.
These steps should be taken first to reset the gas 
regulator safety device:
1.  Turn gas cylinder valve off.
2.  Turn appliance off.
3.  Disconnect the regulator from the gas cylinder.
4.  Wait 30 seconds. 
5.  Reconnect the regulator to the gas cylinder.
6.  Leak test the connection using a soapy water 

solution. Ensure no bubbles appear before 
proceeding.

7.  Slowly open the gas cylinder valve all the way. Do 

not put excessive force on the valve at the full open 
position, to avoid damaging the valve.

8.  Light the appliance as per the instructions provided.
Any modification to the appliance not described in the 
installation instructions may compromise the safety of 
this appliance. Special concern is as follows:
 (1) 

DO NOT bypass thermocouple safety burner;

 (2) 

DO NOT operate appliance without the grate in place;

Clothing or other flammable materials should not be hung 
from the appliance, or placed on or near the appliance.
The area above the burner may be extremely hot. Direct 
contact with these metal surfaces should be avoided in 
order to prevent burns or clothing ignition.

QCC CYLINDER CONNECTION DEVICE

Screw the coupling nut of regulator into the cylinder valve 
outlet. 

Type of Gas

I3/P28-30/ULPG

Consumption

42.2MJ/h

Operating Pressure

2.75kPa

Injector Size

1.84mm

Heater specifications can be found on the data label.

Summary of Contents for Keystone GM142-140

Page 1: ...liquids in the vicinity of this or any other appliance An LPG Cylinder not connected for use shall not be stored in the vicinity of this or any other appliance Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment CARBON MONOXIDE HAZ...

Page 2: ... appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water 12 DO NOT operate this appliance unless it is fully assembled 13 DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION 14 Before use Remove any debris from within t...

Page 3: ...e pilot goes out the unit will automatically turn off REGULATOR SAFETY FEATURE All QCC regulators the part that attaches to the gas cylinder to regulate the flow of gas have a safety feature included that restricts gas flow in the event of a gas leak You can inadvertently activate this safety feature without having a gas leak This typically occurs when you turn on the gas using the appliance contr...

Page 4: ...t in use the gas must be turned off at the cylinder PARTS LIST 3 When connecting the hose to the cylinder tighten the nut to a positive stop by hand 4 Open cylinder valve fully If a leak can be heard at either end of the hose turn cylinder off and tighten joint Wait 5 minutes before re testing and use a soapy water solution to check the joint If bubbles appear the connection will need to be re tig...

Page 5: ...Ignition pin wire 1 5 Burner plate 1 6 Fire table 1 7 Door 1 8 Burner ring 1 9 Nozzle 1 1 2 3 4 5 6 7 8 9 10 11 12 16 14 15 13 17 No Part Name Qty 10 Metal hose 1 11 Safety valve 1 12 Hose and regulator 1 13 Control knob 1 14 Ignitor 1 15 Foot 4 16 Wing screw with nut 1 17 Metal stand 1 ...

Page 6: ...r Tighten the nut to a positive stop by hand STEP 12 Turn on the gas cylinder ensuring that the control knob on the outdoor heater is turned OFF at this point DO NOT ATTEMPT TO LIGHT THE HEATER STEP 13 Use a solution of soapy water dishwashing liquid and water is fine Brush it on or use a spray bottle as shown in the drawing Ensure the connections have a good coating STEP 14a If the connection is l...

Page 7: ...sure proper operation STEP 14b Tighten the connections using a crescent then repeat steps 12 13 STEP 14c The connection is gas tight when no bubbles grow around the gas connection d and as ave a STEP 14a If the connection is leaking bubbles will start to grow in the soapy solution If this happens shut off the gas supply at the cylinder epeat STEP 14c The connection is gas tight when no bubbles gro...

Page 8: ...freezing temperatures Keep the fire table area clear and free from combustible materials gasoline and other flammable vapors and liquids If the fire table is not in use it must be covered to protect from weather or other adverse elements Never use a vacuum cleaner on the lava rocks Installation and repair should be done by a qualified service person The fire table should be inspected at least annu...

Page 9: ...y Regulator hose is pinched Check the regulator hose for bends or kinks Sudden drop in gas flow No gas flow Check if gas cylinder is empty If yes replace Excess flow safety valve has been activated Turn the control knob to OFF Close the gas cylinder valve and disconnect the regulator from the cylinder Turn the control knob to HIGH Wait 1 minute Turner the control knob to OFF Reconnect regulator to...

Page 10: ...10 This page has been intentionally left blank ...