Matters need attention

A. Please read this instruction manual before using the detector.

B. The detector must be used in compliance with the designated procedures of our company. C. The warranty period of this transmitter 

is 12months (starts from the date userget the detector). 

Users should comply with the instructionsin the use of this detector. Any damages or malfunctions caused by improperoperation of users are 

not within the scope of warranty.

D. Repairand replacement of any parts must be operated by trained staff under authorization of our company, using original spare part. 

The operatoris responsible for the liability if users operate the repair of replacement by themselves.

E. There is acid solution inside the transmitter, please do not disassembleit. And pay attention not to damage the frontal membrane of 

the transmitter. If the skin is stained with the acid solution. the right remedy is to flushing the stained skin continuously with clean water for 

1 0minutes.

F. The detector must be calibrated for once each year. The explosion proof sheet parts of the transmitter need to be cleaned 

regularly (blow with low pressure compressedair), otherwise the detection sensitivity will be affected by the dust and impurities clogging 

protection hole.

Notice to Reader

Please read this instruction manual before using the detector

online fixed gas detector 

GD300:XX 

Instruction Manual

www.gasdog.com

[email protected]

+86 773-280-9002

5

Summary of Contents for 41547

Page 1: ...brand sensors and advanced micro process technology with data display fast response high preci sion and good stability Powered by 24V DC with 4 20mA RS485 relay signal output Explosion proof suitable...

Page 2: ...he specific gas concentration in environment or pipeline and alarm With self calibration and zero calibration function makes the detection more accurate and reliable With temperature compensation this...

Page 3: ...0 25 VOL 0 2000ppm 0 1000ppm 0 100 VOL 0 200ppm 0 100ppm 0 100ppm 0 40000ppm 0 250ppm 0 100ppm 0 2000ppm 0 100ppm 0 1000ppm 0 50000ppm 0 5000ppm 0 1000ppm 0 5000ppm 0 100ppm 0 90 VOL 0 50ppm 1 LEL 0...

Page 4: ...Interior Decoration and Renovation Dyestuff Papermaking Pharmacy Health Care Foodstuff Antiseptic Disinfection Chemical Fertilizer Resin Adhesive Pesticide Raw Material Sample Technological Process L...

Page 5: ...iability if users operate the repair of replacement by themselves E There is acid solution inside the transmitter please do not disassembleit And pay attention not to damage the frontal membrane of th...

Page 6: ...tion Ground connection port 5 6 1 2 3 4 7 NC Normally close NO Normally open COM Common 24V 24 positive GND 24 negative 4 20mA 4 20mA analog signal Low Alarm High Alarm Relay Relay Powered Signal outp...

Page 7: ...2 F S H2 2 F S CO2 2 F S C2H4 2 F S NO2 2 F S N2 2 F S TVOC 2 F S NH3 2 F S ASH3 2 F S C3H3N 2 F S F2 2 F S O3 2 F S CL2 2 F S BF3 Range 0 30 VOL 0 1000ppm 0 1000ppm 0 20000ppm 0 10000ppm 0 100ppm 0 2...

Page 8: ...ress to modify the value Press OK to save settings and BACK to cancel 3 Continue to press to enter F03 maximum value setting menu of gas alarm Press OK to modify press to modify the value Press OK to...

Page 9: ...pment wind direction and annual meteorological conditions and even the location of windows and doors in an indoor environment We provide the following suggestions for your reference A Maintain a prope...

Page 10: ...iable ground wire For the wire between the transmitter and the main engine the shorter the better And protect the wire with iron pipe Method of Calibration To guarantee the measurement accuracy of the...

Page 11: ...seconds then the instrument will be calibrated automatically The measured concentration value is consistent with the value set in F 07 4 After calibration left the detector in the air for a while Shut...

Reviews: