MDE-4363G Atlas™ Fuel Systems Owner’s Manual · August 2018
Page 3-45
Operating Sequence for Series 9800 Only
The Atlas Fuel System
3
Dispense fuel into the Prover Can exactly to the zero mark.
The uncalibrated volume
appears.
Notes: 1) If the fuel/DEF is not dispensed within four minutes (approximately) of switching on
the pump handle (or within the time period set by the controller for pulser time out),
the Error Code 574 appears indicating that the pump handle must be switched off to
clear the error. Scrolling will resume after you replace the nozzle.
2) If fuel/DEF dispensing has started but stopped and the pump times out, the
Calibration switch must be turned to “Off” position. Else Error Code 993 appears
as shown in
(99 indicates that the product is not available,
and 3 indicates the product is not calibrated). The procedure must then be restarted
from step
on
.
Figure 3-29: Displaying the Error Code
4
Switch off the pump handle and return nozzle to boot.
After three seconds, the calibration
factor appears on the display for three seconds and then zeros are displayed indicating that the
meter is now calibrated. No further transactions will be allowed until the Calibration switch is
turned to “Off” position.
Note: If an additional transaction is attempted, Error Code 994 appears (99 indicates product
not available, and four indicates calibration mode error). Turn the Calibration switch to
“Off” position and switch off the pump handle to clear the error. The Error Code 993
appears indicating that the Calibration procedure must be restarted from step
on
.
5
Turn the Calibration switch to “Off” position and slide switch cover back over switch.