MDE-4363G Atlas™ Fuel Systems Owner’s Manual · August 2018
Page 3-31
Programming 8800 Models
The Atlas Fuel System
Command Code 5: Test Customer Programmable Preset
Press
5
and then press
ENTER
.
Select Configuration and then press
ENTER
where
0= STOP Test/Program
1= START Test/Program
Depending upon the preset option type testing will convey the following when pressing the
preset buttons:
Five Button Preset (Non-Customer Programmable Preset)
Press
ENTER
after making selections.
1: Program Button 1 (Default 1)
2: Program Button 2 (Default 5)
3: Program Button 3 (Default 10)
4: Program Button 4 (Default 15)
Incremental Preset (Non-Customer Programmable Preset)
Press
ENTER
after making selections.
1: Program Button t (Default 1) Money
2: Program Button 2 (Default 5) Money
3: Program Button 3 (Default 10) Money
4: Program Button 1 (Default 1) Volume
5: Program Button 2 (Default 5) Volume
6: Program Button 3 (Default 10) Volume
(After test is complete, follow programming steps to setup.)
Command Code 6: Memory Clear For Error Code 31 or 35
• Press
6
and then press
ENTER
.
• Press
1
and then press
ENTER
.