Page 6-22
MDE-4334C Atlas Start-up and Service Manual · April 2008
Electronic and Electrical Components
Atlas 9800 Parts
3
Select the appropriate Atlas 9800 Serial EEPROM board (M06656K00X) for the software
type you want to load (refer to
Atlas 9800 Serial EEPROM Board (M06656K00X)
).
4
Ensure that JP1 is not jumpered on the Serial EEPROM Board Assembly (M06656K00X).
Carefully insert into the P14 connector located in the middle of the CPU board.
5
Connect the DC cable to the P10 connector on the M06333KXXXX CPU. Connect AC power
to the pump/dispenser.
6
At this point, on the Serial EEPROM Board Assembly, the green “PWR” and yellow “BUSY”
LEDs will illuminate. A few seconds later, the yellow “BUSY” LED will go off
and the green
“OK” LED should illuminate, indicating download OK. Ensure that the “OK” LED is lit
before proceeding. If the red “NOT OK” LED illuminates, repeat steps
. If the “NOT
OK” LED illuminates after a second attempt, call your service representative or contact
Gasboy Technical Service.
7
Disconnect AC power to the pump/dispenser. Remove the DC cable from the P1 connector on
the power supply.
8
Set Switch SW2-9 to the Open position.
Note: If SW2-9 is left in the Closed Position, the unit will not display software version,
software type, and firmware version during power-up.
9
Carefully remove the Serial EEPROM Board assembly from the P14 connector.
10
Connect the DC cable to the P10 connector on the M06333KXXXX CPU.
11
Connect AC power to the pump/dispenser.
12
Ensure that the displayed software type is correct for the pump/dispenser model that the CPU
is installed in (refer to the table below).
Displayed Software Type
Corresponding Pump Type
“9800 1“
Corresponds to the 9800Q Software:
9852A/Q, 9853A/Q, 9822A/Q, 9823A/
Q/K
“9800 2“
Corresponds to the 9800K Software:
9852K, 9853K
“9840 1“
Corresponds to the 9840Q Software:
9840A, 9840Q
“9840 2“
Corresponds to the 9840K Software:
9840K
“9850“
Corresponds to all 9850 Software:
9850A, 9850Q, 9850K