Page 5-18
MDE-4334C Atlas Start-up and Service Manual · April 2008
Pump Programming
Programming 8800 Series Units
Command Code 2: Program Two-wire/Standalone
To set the mode of operation to Standalone (isolates sale control from the POS) or Two-wire
(unit control via the POS), proceed as follows:
1
Press
2
and then press
Enter
.
2
Press the configuration number and then press
Enter
, where:
• 0 = Standalone mode
• 1 = Two-wire mode
• 2 = Pulse-out mode
Command Code 3: Program Allocation
Programming Volume Allocation basically sets the maximum sale size in units of measure
(gallons for example).
To program the Volume Allocation, proceed as follows:
1
Press
3
and then press
Enter
.
2
Select the Side (1 or 2) and then press
Enter
.
3
Select the Hose/Grade and then press
Enter
.
4
Select the Allocation amount and then press
Enter
.
Note: Repeat the steps above for the other Side, Hose, and Grade.
Command Code 4: Program Manual Blank Display Cash/Volume Preset
Select
The Manual Blank and Five-Button Preset is a dual use code that allows turning off displays
manually or is used to activate different preset modes depending upon the options included
with the unit.
To program Manual Blank Display Cash/Volume Preset Select, proceed as follows:
1
Press
4
and then press
Enter
.
2
Select the Function Code (1 or 2) and then press
Enter
, where:
Function Code 1: Manual Blank Displays
Press the option code and then press
Enter
,
where:
0 = Display Off
1 = Display On
Function Code 2: Cash/Volume Preset Select
Press the option code and then press
Enter
, where:
0 = No 5 Button Preset or Programmable Pump Preset (PPP) installed
1 = Money Preset
2 = Volume Preset
3 = Incremental Preset