Page 5-6
MDE-4334C Atlas Start-up and Service Manual · April 2008
Pump Programming
Configuring the 9800 Series
Figure 5-6: Current Atlas 9800 CPU (M06333KXXXX)
Configuration Steps
Baud Rate
(JP1 on M06333KXXXX CPU and SW1-1 on Previous CPU)
This jumper/switch selects the baud rate for the RS-485 communications. The Gasboy CFN
System and TopKAT Electronic System communicate at 9600 baud.
Baud Rate
JP1/SW1-1
1200
Jumpered/Closed
9600
Open
Mode
(JP2 on M06333KXXXX CPU and SW1-2 on Previous CPU)
This jumper/switch selects the mode in which the pump/dispenser operates. Set the mode to
“Online” if the pump/dispenser communicates via a RS-485 I/F (for example, to a controlling
Gasboy CFN, TopKAT Electronic System). Set the mode to “Standalone” for all others
including Pulse-out I/F configurations (for example, Pulse-out to a Gasboy Series 1000 Fuel
Management System or TopKAT Mechanical System or non-Gasboy systems) or no
controlling system.
Mode
JP2/SW1-2
Standalone
Jumpered/Closed
Online
Open