MDE-4813D CFN PLUS Installation Manual · February 2018
13
1
1
-
-
8
8
.
.
S
S
P
P
E
E
C
C
I
I
F
F
I
I
C
C
A
A
T
T
I
I
O
O
N
N
S
S
The following physical, electrical and environmental specifications are applicable to CFN PLUS:
Supply Voltage:
120 VAC or 240 VAC, 50/60 Hz, manual setting required,
by means of two jumpers (Factory set).
Power Consumption:
1A max.
Operating Temperature:
-22
F to +104
F (-30
C to +40
C)
Storage Temperature:
-22
F to +158
F (-30
C to +70
C)
Humidity:
80% Non-condensing
Dimensions:
W x H x D: 15 x 11.80 x 6.10” (380 x 300 x 155 mm)
Communication Interface:
RS-485 - 9600 bps, Half-Duplex
RS-232
Ethernet RJ-45 - 10 Mbps
Pump Control Maximum Current
(4 Solid State Relay Channels):
Motor maximum: ¾ HP at 115 VAC or 1½ HP at 230
VAC. An additional external relay must be used if the
pump motor exceeds these limitations.
Power supply output voltage to
Pulsar unit
12 VDC +/- 20%, 30 mA max
Pulsar Input High level voltage
Pulsar Input High level sink current
(@15V)
9 to 15 VDC
3 mA
In use “ON” level (Input)
100 - 240 VAC, 50/60 Hz, 2 W (20 mA)
In use “OFF” level (Input)
0 to 20 VAC
1
1
-
-
9
9
.
.
S
S
T
T
A
A
N
N
D
D
A
A
R
R
D
D
S
S
1-9.1. Communication Standards
The CFN PLUS communicates, in its different models, over the following standards:
•
RS-232 link
•