background image

Multi Gas Clip User’s Manual

UM MGC V2.0

8

21 of 21

CONTACT INFORMATION

Gas Clip Technologies, Inc.

610 Uptown Blvd, Suite 4100
Cedar Hill, TX 75104

Toll Free: 

1 (877) 525-0808

Phone: 

+1 (972) 775-7577

Fax: 

+1 (972) 775-2483

E-mail:

info@gascliptech .com

Website:

www .gascliptech .com

LIMITED WARRANTY

Gas Clip Technologies (“GCT”) warrants this product to be free from defects in material and workmanship under normal use and service for a 
period of two years beginning upon the date of activation for all Multi Gas Clip products . Date of activation allowance is limited to the “Activate 
before…” date provided on the shipment box label . This warranty extends only to the sale of new and unused products to the original buyer . 
GCT’s warranty obligation is limited, at GCT’s option, to refund of the purchase price, repair, or replacement of a defective product that is 
returned to a GCT authorized service center within the warranty period . In no event shall GCT’s liability hereunder exceed the purchase price 
actually paid by the buyer for the product . This warranty does not include: (1) Fuses, disposable batteries, or routine replacement of parts due 
to the normal wear and tear of the product arising from use . (2) Any product which in GCT’s opinion, has been misused, altered, neglected or 
damaged by accident or abnormal conditions of operation, handling, or use . (3) Any damage or defects attributable to repair of the product 
by any person other than the authorized dealer, or installation of unapproved parts on the product . The obligations set forth in this warranty 
are conditional on: (1) Proper storage, installation, calibration, use, maintenance, and compliance with the user’s manual instructions and 
any other applicable recommendations of GCT . (2) The buyer promptly notifying GCT of any defect and, if required, promptly making the 
product available for correction . No goods shall be returned to GCT until receipt by the buyer of instructions from GCT . (3) The right of GCT to 
require that the buyer provide proof of sale or packing slip to establish that the product is within the warranty period . The buyer agrees that 
this warranty is the buyer’s sole and exclusive remedy and is in lieu of all other warranties, expressed or implied, including, but not limited 
to, any implied warranty or merchantability or fitness for a particular purpose . GCT shall not be liable for any special, indirect, incidental, or 
consequential damages or losses, including loss of data, whether arising from breach of warranty or based on contract, tort, or reliance on any 
other theory . Some countries or states do not allow limitation of the term of an applied warranty, or exclusion or limitation of incidental or 
consequential damages . The limitations and exclusions of this warranty may not apply to every buyer . If any provision of this warranty is held 
invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision . 

Summary of Contents for Multi Gas Clip Infrared

Page 1: ...Multi Gas Clip Infrared Multi Gas Clip Pellistor G A S C L I P T E C H C O M User s Manual...

Page 2: ...play Details 6 Alarms 7 Default Alarms 7 Alarm Behavior 7 Detector Menus Options 8 Main Menu 8 Status Menu 8 Option Menu 9 Adjustable Options 9 Detector Maintenance 11 Bump Testing 11 Manual Bump Test...

Page 3: ...cones lead compounds e g tetraethyl lead sulfur compounds phosphorus halogenated hydrocarbons and aerosols Exposure to poisons may impair the accuracy and or response time of the detector This applies...

Page 4: ...nance LEDs 3 Display 4 Audible Alarm Port 5 Power Menu Button 6 Dual Tox Sensor Port 7 LEL Sensor Port 8 O2 Sensor Port 9 Calibration Cap Ports 10 Infrared IR Communication Window 11 Alligator Clip wi...

Page 5: ...LOW BAT and then turn off again Once activated the detector will begin to display gas readings immediately Each sensor will show a chasing 0 for the sensor reading while it is stabilizing and being s...

Page 6: ...ime to apply gas The Battery Charge Level 3 is displayed in a 3 bar battery icon as well as a percentage The percentage calculation is approximate and can be used to provide a rough estimation of the...

Page 7: ...on fast LED flash Low Battery 20 minutes remaining single beep flash battery icon on 10 minutes remaining single beep flash battery icon flashing 5 minutes remaining continuous beep flash every 5 seco...

Page 8: ...lay in the following order 1 L CAL the last calibration date 2 CAL DUE or CAL IN ___ d denotes if a calibration is due or how many days until it is due 3 L BUMP the last bump test date 4 BUMP DUE or B...

Page 9: ...the detector when to go into alarm Alarm limits may be disabled by setting them to zero Caution Confirm alarm levels with local laws regulations before operation SAFE Display SAFE will be displayed i...

Page 10: ...LEL typically 2 5 in North America and 2 2 in Europe Language The detector will display all its text prompts in any of six languages English German French Spanish Italian or Portuguese Note OL Err and...

Page 11: ...en show in the following order 1 Current Date Time DD MON TT TT below stand for Day Month Time 2 User Programmed Text Message 3 SHOW STATUS Prompt When the screen displays SHOW STATUS quickly press an...

Page 12: ...eturn to normal operation after a short period of time The bump due date will be automatically reset based on the new bump date The bump test will be recorded in the Bump Log When a bump test interval...

Page 13: ...signate which sensor did not pass The failed sensor will be disabled and will need to be replaced see Err in Failures FAQ s section During a manual bump test the audible visual vibrating prompting to...

Page 14: ...d down the power menu button through the shutdown sequence see Turning Off the Detector section and the calibration countdown sequence that follows it Display will show During these two countdowns the...

Page 15: ...MGC Vehicle Charger MGC Charging Station or MGC Multi Charger all authorized GCT Multi Gas Clip Optional Accessories The detector will cycle the battery icons in a charging fashion until the battery i...

Page 16: ...ump tests are differentiated from normal events when the alarm condition occurs inside of an MGC Dock or MGC Wall Mount Dock or when the detector is manually bump tested according to the Bump Testing...

Page 17: ...Air Stone Particulate Filter MGC Calibration Cap 10 ft Sampling Hose and Hand Aspirator Pump Assembly with Quick Connect hose 3 ft Calibration Test Hose with Quick Connect 0 5Lpm Regulator with Quick...

Page 18: ...d availability FAILURES FAQ S Err If a sensor is displaying Err this sensor has failed and is therefore disabled Contact GCT for either warranty replacement or replacement sensor s BUMP DUE If the det...

Page 19: ...n activation Sensors battery and circuitry tests run continuously Ingress Protection IP 67 Warranty Full 2 years Gas Range Resolution Accuracy T90 Gases H2S 0 100 ppm 0 1 2 ppm 30s CO 0 500 ppm 1 5 pp...

Page 20: ...ent has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful int...

Page 21: ...to repair of the product by any person other than the authorized dealer or installation of unapproved parts on the product The obligations set forth in this warranty are conditional on 1 Proper storag...