Multi Gas Clip User’s Manual
UM MGC V2.0
8
18 of 21
•
Replacement Filters:
* Filter - Pack of 10 (P/N: MGC-FILTER-10)
* Filter - Pack of 50 (P/N: MGC-FILTER-50)
•
Replacement Detector Components
– Various authorized replacement/spare parts for Multi Gas Clip detectors
are available
See the GCT website (www .gascliptech .com) for further details or contact GCT for pricing and availability .
FAILURES/FAQ’S
•
“Err”
- If a sensor is displaying
“Err”
, this sensor has failed and is therefore disabled . Contact GCT for either
warranty replacement or replacement sensor(s) .
•
“BUMP DUE”
- If the detector is displaying
“BUMP DUE”
, the detector is either due for a bump test because of a
scheduled test or has failed its last bump test . Refer to the
Bump Testing
section for more details .
•
“CAL DUE”
- If the detector is displaying
“CAL DUE”
, the detector is due for a calibration because of a scheduled
interval . Refer to the
Calibration
section for more details .