Power Budget Calculations for 6KL Modules with Fiber Media 

 
 

Receiver Sensitivity and Transmitter Power are the parameters necessary to 

compute the power budget. To calculate the power budget of different fiber media 
installations using Magnum products, the following equations should be used:

 

OPB (Optical Power Budget) = P

T

(min) - P

R

(min) 

      

 where P

= Transmitter Output Power, and P

R

 = Receiver Sensitivity 

 
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) 
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] 
 

where the “Cable Loss” for 62.5/125 and 50/125

μ

m (M.m) is 2.8 dB/km,  

 

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, 

 

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km 

 

and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LX25) 

 

and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km (ZX40) 

 

and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (ZX70) 

See 

http://www.garrettcom.com/techsupport/power_budget.pdf

 for more information on 

Power budget calculations 

 

5.0 

Magnum 6KL Managed Edge Switch Port Modules 

 

This chapter describes each Port Module (PM), including appearance, 
functionality, and status displays.

 

5.1 6KL 

Modules

 

 

An important feature of the Magnum 6KL is the use of Port Modules for 

flexible mixed-media connectivity to RJ-45 copper and various fiber media. The first 
four ports (1,2,3 & 4) of the Magnum 6KL Switches are fixed RJ-45 copper ports with 
dual-speed 10/100Mbps auto-negotiating capability. Additionally the switch can accept 
up to two Port Modules to provide the user with up to 6 additional ports (10 total) 
providing a wide selection of Ethernet copper and fiber media connections with 10, 100 
and 1000Mbps capability and up to 70km. 

 Note:   The 6KL Port modules are not identical to the port modules used in other 

6K products such as the 6K25e and 6K16V.   For information about other 

6K products, please see the applicable manual.  For a list of 6KL Port 

Modules, refer to Section 1.2 

Each 6KL Port Module (PM) is individually described in the following sections. 

Summary of Contents for magnum 6kl

Page 1: ...www GarrettCom com Magnum 6KL Managed Edge Switch Hardware Installation and User Guide...

Page 2: ...viceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with Magnum 6KL Switch products consult Section 6 Troubleshooting Copyr...

Page 3: ...reil respecte toutes les exigences du R glement sur le mat riel du Canada Cet appareil est Classe A Electrical Safety requirements 1 This product is to be installed Only in Restricted Access Areas Ded...

Page 4: ...l Mounting the Magnum 6KL 21 3 3 1 Mounting Dimensions for 6KL with metal brackets 22 3 4 Powering the Magnum 6KL Managed Edge Switch 24 3 5 Alarm Contacts for monitoring internal power and Software T...

Page 5: ...RJ45 Slot B 41 5 1 22 6KL 2GSFP 2 x Gigabit SFP Slot B 41 6 0 TROUBLESHOOTING 42 6 1 Before Calling for Assistance 42 6 2 When Calling for Assistance 42 6 3 Return Material Authorization RMA Procedur...

Page 6: ...ocol IEEE 802 1d Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control IEEE 802 3ad Link Aggregation Trunking IEEE 802 1x Port based Network...

Page 7: ...t Temperature 40 to 140 F 40 to 60 C for UL60950 and Component Parts rating 40 to 195 F 40 to 85 C for IEC 60068 Type Test short term rating Storage Temperature 60 to 210 F 50 to 100 C Ambient Relativ...

Page 8: ...models This provides for continuity of operation when either of the DC input sources is interrupted See Appendices B and C The Dual Source Terminal Block is marked A A B B Management Console connector...

Page 9: ...6KL 12VDC Same as 6KL 24VDC except the power input is 12VDC Magnum 6KL 48VDC Same as 6KL 24VDC except the power input is 48VDC Magnum 6KLP 48VDC PoE same as 6KL 48VDC except the four 10 100 ports are...

Page 10: ...L4 2SSC2RJ adds two SM 20Km 100Mb SC fiber and two 10 100 copper ports 6KL4 4SSCL adds four SM 40Km 100Mb SC fiber ports 6KL4 4MST adds four MM 2Km 100Mb ST fiber ports 6KL4 2MST2RJ adds two MM 2Km 10...

Page 11: ...X 1550nm wavelength 40Km SFP ZX70 Gb SFP transceiver 1000Mb ZX 1550nm wavelength 70Km MNS 6K License MNS 6K managed software is pre loaded from the factory S RING Key S Ring and RS Ring Redundancy Man...

Page 12: ...ckage should contain 1 Magnum 6KL Managed Edge Switch base unit configured with user selected port module options installed 2 Set of two metal vertical mounting brackets with screws to the case 1 6KL...

Page 13: ...switched hardened Ethernet network infrastructure connecting edge devices such as PLCs and IEDs with upstream switches or routers Designed for use in industrial applications such as factory floors an...

Page 14: ...of bursty data traffic and priority streaming traffic for video surveillance and cell tower applications are present Magnum 6KL Managed Edge Switches have heavy duty steel cases and are readily availa...

Page 15: ...lculated the result of indiscriminate cut through forwarding is greater traffic congestion especially at peak activity Since collisions and bad packets are more likely when traffic is heavy the result...

Page 16: ...Magnum MNS 6K Software User guide in pdf format a separate document normally accessible via your web browser at ftp ftp garrettcom com or FTP client program at ftp GarrettCom com using user m6kuser p...

Page 17: ...s a security violation or an S Ring fault condition Vertical mounting for efficient convection cooling no fans extended temperature Mounting brackets for vertical mounting are included DIN Rail mounti...

Page 18: ...ity of 100Mbps fiber and copper ports as well as single or dual Gigabit 1000Mb ports with industry standard LAN management software Magnum 6KL Switches are easily used in a variety of applications inc...

Page 19: ...here the factory floors are networked with Ethernet based mixed media LANs equipped with PLCs computers for taking readings and data from Machines Client Server databases etc and sending these importa...

Page 20: ...disconnection or power failure can bring the whole thing down a ring switch can be reconfigured and up and running in milliseconds The ring topology of the network consists of high speed LAN segments...

Page 21: ...and managed to easily monitor the whole setup The Magnum managed edge switch easily qualifies for this requirement with the various features and modularity it has Loaded with MNS 6K management softwar...

Page 22: ...erloading of the building s electrical circuits 5 If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised earthing path This sec...

Page 23: ...nformation 3 2 1 Connecting Twisted Pair CAT3 CAT5 UTP or STP The RJ 45 ports of the Magnum 6KL can be connected to the following two media types 100BASE TX and 10BASE T CAT 5 cables should be used wh...

Page 24: ...mmended to use when making 1000BASE TX connections In either case the max distance for unshielded twisted pair cabling is 100 meters 328 ft The following procedure describes how to connect a 1000BASE...

Page 25: ...advised not to remove and insert a SFP transceiver frequently as this may shorten its useful life Note Always use an ESD wrist strap while handling the SFP transceivers since the SFP modules are stati...

Page 26: ...via MNS 6K software for verifying the validity of SFP Gigabit ports 3 3 DIN Rail Mounting the Magnum 6KL The Magnum 6KL is designed for use in a factory floor industrial environment It is available wi...

Page 27: ...is also advisable to mount the unit with space for air movement around the top and the sides typically a minimum of 1 inch Note The metal brackets supplied hold the back of the 6KL unit out from the...

Page 28: ...l Mounting position 2 The unit is mounted using the brackets as shown in the illustration above The spacing for the mounting screws into the supporting wall or panel is a rectangle 2 81 x 8 58 inches...

Page 29: ...ated problems or damage to the unit Power input options are available to suit the 6KL Switches to special high availability communications and or heavy industrial grade applications including 12VDC 48...

Page 30: ...the user s monitoring system The second NC Alarm Contact is held closed when there is power on the main board inside of the Switch This provides a Hardware Alarm labeled H W because the NC contacts wi...

Page 31: ...P site Also available on GCI website at http www garrettcom com techsupport sw_downloads htm 3 6 1 RJ45 Console port Serial port pin assignments RJ45 6KL Console port connector Pin Signal Description...

Page 32: ...hed ports which must be configured through MNS software per unit as per the requirement The internal functions of both are described below Filtering and Forwarding Each time a packet arrives on one of...

Page 33: ...ially available Fast Ethernet media converters mostly do not support auto negotiation properly and require that the switched port to which they are connected be at the 100Mb fixed speed Attachments to...

Page 34: ...ort to a 10 Mb port and the 10Mb port is unable to keep up It can also occur when multiple 100Mb ports are attempting to transmit to one 100Mb port and in other protracted heavy traffic situations Mag...

Page 35: ...e is 0 2 dB km ZX70 See http www garrettcom com techsupport power_budget pdf for more information on Power budget calculations 5 0 Magnum 6KL Managed Edge Switch Port Modules This chapter describes ea...

Page 36: ...upplied to the unit RJ45 Standard 1 ON 100Mb OFF 10Mb 2 ON Link BLINKING Activity 3 ON Full Duplex OFF Half Duplex RJ45 PoE 1 ON 100Mb OFF 10Mb 2 ON Link BLINKING Activity 3 ON Full Duplex OFF Half Du...

Page 37: ...ING Activity 2 ON Full Duplex OFF Half Duplex LC Fiber 1 ON Link BLINKING Activity 2 ON Full Duplex OFF Half Duplex SC Fiber 1 ON Link BLINKING Activity 2 ON Full Duplex OFF Half Duplex ST Fiber 1 ON...

Page 38: ...half duplex mode A twisted pair cable must be connected into an RJ 45 port and the Link LK indicator for that port must be ON indicating there is a powered up device at the other end of the cable in...

Page 39: ...tor with both fiber strands terminated in one housing that cannot be improperly inserted Each port has a Link Activity L A LED indicating proper connectivity Link with the remote device when lit and b...

Page 40: ...This module provides the same functions as the Multimode version see Section 5 1 2 and 5 1 3 for more details The 6KL4 2SLCL2RJ 4 port Fiber module provides two 100Mb Singlemode LC Fiber ports suppor...

Page 41: ...ports support the standard distance of 100m on each port see Sections 5 1 2 and 5 1 7 for more details 5 1 9 6KL4 4MSC 4MST 4FLST 2FX2FLMST Slot C 4 x SC Multimode or 4 x ST Multimode The 6KL4 4MSC sh...

Page 42: ...s the same functions as the Multimode version see Section 5 1 9 for more details 5 1 11 6KL4 2MSC2RJ 6KL4 2MST2RJ Slot C 2 x SC Multimode or 2 x ST Multimode 2 x RJ45 The 6KL4 2MSC2RJ shown 4 port Fib...

Page 43: ...ations The Singlemode connectors supporting distances up to 20Km and Multimode connectors supporting up to 2Km distances 5 1 14 6KL4 1ML1SLC2RJ Slot C 1 x LC Multimode 1 x LC Singlemode 2 x RJ45 The 6...

Page 44: ...e 5 1 2 and 5 1 3 for more details 5 1 17 6KL4 1MT3RJ 1 x MTRJ Multimode 3 x RJ45 Slot C The 6KL4 1MT3RJ 4 port Fiber Copper module provides one 100Mb Multimode MTRJ Fiber port supporting distances up...

Page 45: ...ice on that port When non PoE devices are connected the PoE LED is OFF Operation of Ethernet data traffic is not affected by PoE LINK and ACTIVITY LEDS are combined on the PoE modules into one LED tha...

Page 46: ...Slot B The 6KL 2GSFP 2 port Fiber Gigabit module provides two SFP open transceiver locations Transceivers are available with both multi mode 850nm 550m 1310nm 2km single mode 1310nm 10km and 25km and...

Page 47: ...etwork are interoperable 2 Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About...

Page 48: ...URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Name and phone number of your contact person Name of your compan...

Page 49: ...esponsible for your return shipping charges 4 Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants it...

Page 50: ...wer Consumption 15 watts typical for a fully loaded fiber model with 2Gb 10 watts typical for 8 ports copper and 100Mb fiber 12VDC Power Input nominal range 10 to 15VDC 24VDC Power Input nominal range...

Page 51: ...also frequently used for computer system backup management and operations monitoring equipment The 24V and 125VDC options are particularly useful in the industrial environment where it is common for...

Page 52: ...t be connected to the post labeled B4 1 UL Requirements for DC powered units CAUTION 48VDC products shall be installed with a readily accessible disconnect device in the building installation supply c...

Page 53: ...ach at 88 150 VDC Power Supply Internal 250VDC Dual Source model Dual Src 250V DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate...

Page 54: ...t DC input is present the Switch will receive power if the other DC input is absent or even if it is connected with reverse polarity or shorted or grounded d Reverse polarity connections if they shoul...

Page 55: ...the power supply and determine the lead which is more ve potential The more ve voltage lead from a ve or ve power supply must be connected to the post labeled The connection procedure is straightforw...

Page 56: ...ase 2 top 2 rear and discard screws b Slide 6KL cover back approx 1 2 to disengage from case c Lift off cover to expose the 6KL interior See also the photo 1d below d Remove existing Slot C panel by r...

Page 57: ...om Step 1d Remove panel blank shown Step 2a Add new panel Step 2b Remove Main PCB screws Step 2c Install stand offs Step 3a Locate Main PCB connector Step 3b Guide module into panel Step 3c Secure mod...

Reviews: