Magnum 10KG Managed Switch Installation and User Guide
07/12
3
www GarrettCom com
.
.
DC Power Supply (Internal, floating ground)
DC Power Connector:
Terminal block
(L) 24/48VDC Power Input (range 22 to 60VDC)
(H) AC/DC Power Input (range 90-250V AC or DC)
Standard 3-screw Terminal block: “ -, +, GND ”
for PoE applications:
PoE+ 802.3at: (L) 48VDC Power Input (range 52 to 56VDC)
Standard 2-screw Terminal block: “+, -“
Power Consumption:
55 watts Max. (for a fully-loaded model w/ 8Gb ports, 16 100Mb fiber ports)
AC Power Supply (Internal)
AC Power Connector:
IEC-320/C14 type, male recessed
100-240VAC Power Input, 47 to 63 Hz (auto-ranging)
Power Consumption:
30 watts typical with 32 fully-loaded copper ports
Management Console Connector
RJ45, see details at Section 3.6
10KG Mounting:
Rack-mounting, standard method.
Unit supplied with rack-mounting brackets for mounting in a 19” rack.
Agency Approvals and Standards Compliance:
ANSI/UL 60950-1, Issued: 2007/03/27 Ed:2 UL Standard for Safety for
Information Technology Equipment Safety Part 1: General Requirements’
CSA C22.2 No. 60950-1, Issued: 2007/03/01 Ed:2 Standard for Safety for
Information Technology Equipment Safety Part 1: General Requirements’
Emissions meet FCC Part 15 Class A
IEEE 1613 Class 2 Environmental Standard for Electric Power Substations
See
also
Note for Power Substations
in Section 3.2.1 and 5.1.2
IEC 61850-3 EMC and Operating Conditions Class C for Power Substations
NEMA TS-2 for Traffic Control
EN50155 for Railways
Warranty:
Refer to current Belden Americas Terms & Conditions for
warranty
information