A.3.2 Serial Port Statistics
The Serial Port Statistics menu, for ports S1 to S32, is shown in
Figure A-11
and the fields are described in
Table A-7
. The statistics can be updated by pressing
<Enter>
while viewing this screen or cleared by
pressing
<CTRL-D>
.
Figure A-11. Serial Port Statistics Menu
Table A-7. Serial Port Statistics Attributes
Field Description
Port Number
The number of the port whose statistics are being displayed.
Enabled
Date and time the port was enabled.
Cleared
Displays date and time when statistics were last cleared using the <CTRL-D> option.
Current Status
Indicated whether a connection is Up or Down. Also may show the Packet and Cell
states for diagnostic purposes.
Connection type
Fixed DTE.
Flow Control Status
Indicates whether flow control has been received (Yes /No) or sent (Yes/No) and shows
the number of characters discarded after flow control is sent. Flow control can be XON/
XOFF or data set signals.
Incoming Signals
Status (On/Off) of incoming data set signals.
Characters
The number of asynchronous characters sent/received.
Breaks
The number of line breaks received.
Call Attempts
Succeeded
Failed
The total number of call attempts, to and from, followed by the number of calls
successfully received (Succeeded) and Failed.
Statistics for Async port
S1: SERIAL1
Enabled: 7-14-04 12:33:29
Cleared: 7-31-04 10:56:01
Current status:
Down (Ps 2 Cs 0)
Connection type: DTE
Flow control status:
Incoming signals:
Received
= No
CD
= Off
Sent
= No
CTS = Off
Character discard
=
0
To device
From device
Characters
0
0
Parity errors
=
0
Breaks
0
Framing errors
=
0
Call attempts
0
0
Overruns
=
0
Succeeded
0
0
Unable to store character
=
0
Failed
0
0
__________[DynaStar_24]___________
Press <RET> for statistics update
Press ESC to return to previous menu