2.2
TOUCHPADS
Eight touchpads on the overhead Control Panel perform all control functions:
2.2.1
STANDBY
When this touchpad is pressed, the unit goes into a low power mode, ready to be returned to full
operation when the
OPERATE
pad is touched. When STANDBY is displayed on the LCD, the green
READY light is not visible and no processing can take place in the unit. It is important to remember
that the Power Switch located on the Battery Back-up Module (See Section 11.6) should be set to its
OFF position anytime the system is being stored and anytime the system is not in use and is not con-
nected to AC power for more than 24 hours.
2.2.2
OPERATE
Whenever this touchpad is pressed, the CS 5000 activates all circuits, initiates a self-diagnosis pro-
gram and places the unit in the Operate Mode within fifteen (15) seconds. This diagnostic program for
instant fault detection can be activated at any time by touching this
OPERATE
pad. If any faults are
ever found, they will be immediately reported on the LCD display. (See Section 4.)
2.2.3
COUNTER
When this touchpad is pressed, the traffic count is displayed on the LCD display. Pressing and hold-
ing this touchpad for ten (10) seconds causes the counter to return to zero (0). Whenever the LCD is
displaying information other than the current traffic count, pressing this touchpad will cause the count
to appear along with the Sequence Number of changes that have been made to Program/Sensitivity
settings. CT (Number) and SEQ (Number) will appear. Each time the Program/Sensitivity Mode is
accessed, the Sequence Code that appears on the LCD will be advanced one number. It is recom-
mended that a written notation be made on the Operations Worksheet (see Section 11.1) whenever
this code is accessed, explaining reasons for the access. If the
ACCESS
touchpad has been pressed
and an improper access code has been entered, a * will appear before the sequence number (SEQ
*37). This indicates that an unsuccessful (unauthorized) attempt has been made to gain access to
the Program/Sensitivity setting.
2.2.4
VOLUME
When this touchpad is pressed, the volume level of the unit’s audible alarm will be shown on the LCD
display and the actual volume of the alarm will be heard. The + and - touchpads can be used by opera-
tors to raise or lower the volume. Press
OPERATE
to return to the operate mode.
2.2.5
+ AND -
These touchpads will be used to increase or decrease various numerical settings and for certain On/
Off functions.