CS 5000
User Manual
©2009 GARRETT METAL DETECTORS 39
PN 1530100 REV H
Procedure:
• Disconnect units from power line;
• Open Access Door of Detection Unit;
• Remove three (3) screws that hold controller cover;
• Use synchronization wire (18 to 24-gauge, 2 conductor) between units; connect as shown;
• Set the end unit to MASTER CHANNEL A and ensure that this unit is connected to either AC
power or battery power at all times;
• Replace covers and reconnect power;
• Set all other units to Slave;
• Repeat pattern of CHANNELS A, C, and D for any additional units.
11.4
AC & DC CONTROL
11.4.1
AC CONTROL
Connection of an external alarm, locking device or other component may be made as shown below.
The optically-isolated triac output will conduct only during the time that the Red ALARM light is illu-
minated. It is recommended that the control not exceed 48Vrms and 100mA. The output is electri-
cally isolated from ground.
• Open Access Door of detection unit;
• Remove three (3) screws that hold controller cover;
• Connect the relay or device to control;
• Replace cover and reconnect power.
11.4.2
DC CONTROL
The three drawings that follow illustrate alternate methods of connecting an external device which
has requirements of low voltage direct current. The output is an open collector configuration capable
of switching 15V at 100mA or less, which includes connections to computing devices and other
equipment requiring low level DC.