Troubleshooting
USER MANUAL
Basic indications
Solid green
Twinbox ready, waiting for EV to
connect
Flashing green
EV connected, waiting to start
charging or charging complete
Fast flashing green
RFID reader ready, waiting to
read tag
Shifting blue intensity
Charging in progress
Solid blue
RFID tag accepted, charging
starts within 2 min
Slow flashing blue
Remote enable signal is
disabled, Charging deactivated
in web-interface or Scheduled
charging not active
Fast flashing white
Indentification signal
Error indications
Error type
Action
Solid yellow
Charging cable error
Check the charging cable
Flashing yellow
EV outlet locking function error
Check the EV outlet, contact local
electrician
Solid red
RCCB tripped or error signal
from EV
Reset RCCB
Solid red for 3s
RFID tag not accepted
Check your RFID tag
Fast red flash
DC fault detected
Automatically reset after 15min or at
restart of charging process
Shifting red/green/yellow
DC fault-detection hardware
error
Contact local electrician
33