![GARO Nova GTC Assembly Instructions / End User Instruction Download Page 12](http://html.mh-extra.com/html/garo/nova-gtc/nova-gtc_assembly-instructions-end-user-instruction_567632012.webp)
Resetting/Conditioning of RCCB
In the event of overload/earth fault, the built in RCCB/RCBO
can trip, see picture 12. These components also need to be
conditioned by pressing the test button every 6 month.
Procedure to reset/condition:
1. Disconnect the EV from the Nova
2. Open the front door.
3. Reset the RCCB (B). Conditioning means that first press the test
button (A) and then reset the RCCB (B).
4. Close the front door.
Front door should be closed and locked to achieve IP44 class.
A
B
(picture 12)
Left/vänster
Right/höger
12