Post Installation Configuration & Checkout
190-01499-02
GTX 3X5 Transponder TSO Installation Manual
Rev. 9
Page 6-19
Photocell Slope
Configures the sensitivity of the photocell input level. Adjusting the slope higher results in a greater display brightness
change for a given increase in the photocell input level. The range is 0 to 100.
Offset
Adjusts the lighting level up or down for any given photocell input level. This field has a range of 0 to 100. Use the
offset setting to match lighting curves with other equipment in the panel.
Figure 6-24 Photocell Transition, Slope, and Offset Page
Lighting Bus Input Vltg
Configures the voltage of the lighting bus source. Selections are:
Figure 6-25 Lighting Bus Input Voltage Page
Display and Bezel Key Lighting Slope
Configures the sensitivity of the display or bezel keys for any given lighting bus input level. Set the slope higher for a
brighter display for a given increase in the lighting bus input level. This field has a range of
0 to 100.
Display and Bezel Key Offset
Configures the lighting level up or down for any given lighting bus input level. This field has a range of
0 to 100. Use the offset setting to match lighting curves with other equipment in the panel.
• 14 VDC
• 28 VDC
• 5 VDC
• 5 VAC