Page 4-20
500W Series Installation Manual
Rev. D
190-00357-02
4.8.2.4 Flag
Pin Name
Connector
Pin
I/O
VOR/LOC +FLAG
P5006
3
Out
VOR/LOC -FLAG (VOR/LOC COMMON)
P5006
4
Out
GLIDFLAG
P5006
30
Out
GLIDDOWN/-FLAG (GLIDESLOPE
COMMON)
P5006 31
Out
The Flag output is capable of driving up to three 1000
Ω
meter loads. When valid information is present
(Flag OUT OF VIEW) the Flag output is 375 ±80 mV DC
.
When invalid information is present (Flag IN
VIEW) the Flag output is 0 ±25 mV DC.
4.8.2.5 OBS
Pin Name
Connector
Pin
I/O
VOR OBS ROTOR C
P5006
9
Out
VOR OBS ROTOR H (GROUND)
P5006
10
Out
VOR OBS STATOR D
P5006
13
In
VOR OBS STATOR F
P5006
12
In
VOR OBS STATOR E/G (VOR/LOC COMMON)
P5006 11
Out
VOR OBS ROTOR C and H are a buffered 500 Hz output that is intended to drive the OBS rotors. VOR
OBS STATOR D and VOR OBS STATOR F are each phase and amplitude shifted version of the VOR
ROTOR C output. Each pair is intended to read one of the two windings of the indicator’s OBS stator.
4.8.2.6 VOR/LOC
COMPOSITE
Pin Name
Connector
Pin
I/O
VOR/LOC COMPOSITE OUT
P5006
8
Out
With a Standard VOR Test Signal applied, VOR/LOC COMPOSITE OUT is 0.5 ± 0.1 V
RMS
into a 10
k
Ω
load. With a Standard Localizer Centering Test Signal applied, VOR/LOC COMPOSITE OUT is
0.350 ±0.05 V
RMS
into a 10 k
Ω
load.
4.8.2.7 ILS
ENERGIZE
Pin Name
Connector
Pin
I/O
ILS ENERGIZE
P5006
29
Out
The driver output voltage is not more than 1.0 V when sinking 20 mA. The maximum off state leakage
current with respect to GND is less than 10
μ
A.
4.8.3
VOR/ILS Indicator Configuration
None.
4.8.4
VOR/ILS Indicator Calibration and Checkout
Refer to Sections 5.3.12 and 5.3.13 for the VOR/LOC/GS checkout.
4.8.5
VOR/ILS Indicator Interconnect
Refer to Figure H-19 for the VOR/ILS indicator interconnect.
Summary of Contents for GNS 530W
Page 2: ...500W Series Installation Manual 190 00357 02 Rev D...
Page 130: ...Page 7 4 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 132: ...Page 8 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 134: ...Page A 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 136: ...Page B 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 137: ...500W Series Installation Manual Page C 1 190 00357 02 Rev D Appendix C RESERVED...
Page 138: ...Page C 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 148: ...Page E 6 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 150: ...Page F 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 160: ...Page G 6 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 162: ...Page H 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 188: ...Page H 28 500W Series Installation Manual Rev D 190 00357 02 Figure H 16 GTX 330 Interconnect...
Page 194: ...Page H 34 500W Series Installation Manual Rev D 190 00357 02 Figure H 20 RMI OBI Interconnect...
Page 198: ...Page H 38 500W Series Installation Manual Rev D 190 00357 02 Figure H 24 TAWS Interconnect...
Page 211: ...500W Series Installation Manual Page H 51 190 00357 02 Rev D Figure H 33 Switches Interconnect...
Page 215: ......
Page 216: ......