500W Series Installation Manual
Page E-5
190-00357-02
Rev. D
E.6.3
SHADIN “S” FORMAT
<STX>
SA012<CR><LF>
"SA" (ASCII characters); "012" represents indicated Air Speed (knots)
SB345<CR><LF>
"SB" (ASCII characters); "345" represents true Air Speed (knots)
SC678<CR><LF>
"SC" (ASCII characters); "678" represents Mach Speed (thousandths)
SD<+/->9012<CR><LF>
"SD" (ASCII characters); sign; "9012" represents pressure altitude (tens of feet)
SE<+/->3456<CR><LF>
"SE" (ASCII characters); sign; "3456" represents density altitude (tens of feet)
SF<+/->78<CR><LF>
"SF" (ASCII characters); sign; "78" represents outside air temperature (Celsius)
SG<+/->90<CR><LF>
"SG" (ASCII characters); sign; "90" represents true air temperature (Celsius)
SH123<CR><LF>
"SH" (ASCII characters); "123" represents wind direction (degrees from north)
SI456<CR><LF>
"SI" (ASCII characters); "456" represents wind speed (knots)
SJ<+/->78<CR><LF>
"SJ" (ASCII characters); sign; "78" represents rate of turn (degrees per second)
SK<+/->901<CR><LF>
"SK" (ASCII characters); sign; "901" represents vertical speed (tens of ft/minute)
SL234<CR><LF>
"SL" (ASCII characters); "234" represents heading (degrees from north)
SM5678<CR><LF>
"SM" (ASCII characters); "5678" represents fuel flow, right (tenths gallons/hour)
SN90123<CR><LF>
"SN" (ASCII characters); "90123" represents fuel used, right (tenths gallons)
SO4567<CR><LF>
"SO" (ASCII characters); "4567" represents fuel flow, left (tenths gallons/hour)
SP89012<CR><LF>
"SP" (ASCII characters); "89012" represents fuel used, left (tenths gallons)
SQ345<CR><LF>
"SQ" (ASCII characters); "345" represents error log/reason indicator
SR67890<CR><LF>
"SR" (ASCII characters); "67890" represents fuel remaining (tenths gallons)
SS123<CR><LF>
"SS" (ASCII character); "123" represents ground speed (knots)
ST456<CR>LF>
"ST" (ASCII character); "456" represents track (degrees)
SU789012<CR><LF>
"SU" (ASCII character); "789012" represents distance to waypoint (hundredths nautical miles)
SV<E/W>345<CR><LF>
"SV" (ASCII character); “E” represents East, “W” represents West; "345" represents magnetic
variation (tenths degrees)
SW<N/S>67 8901<CR><LF>"SW" (ASCII character); “N” represents North, “S” represents South; "67 8910" represents current
latitude (degrees, minutes, hundredths of minutes)
SX<E/W>234 5678<CR><LF>"SX" (ASCII character); “E” represents East, “W” represents West; "234 5678" represents
current longitude (degrees, minutes, hundredths of minutes)
SY<L/R>90<CR><LF>
"SY" (ASCII character); “L” represents Left, “R” represents Right; "90" represents drift angle
(degrees)
Sa<+/->1234<CR><LF>
"Sa" (ASCII character); sign; "1234" represents barometric corrected altitude (tens of feet)
Sb56.78<CR><LF>
"Sb" (ASCII character); "56.78" represents current barometric pressure setting (inches Hg)
S*901<CR><LF>
“S*” (ASCII character); "901" represents checksum
<ETX>
Where:
<STX> start-transmit character (0x02)
<CR>
carriage-return character (0x0d)
<LF>
line-feed character (0x0a)
<+/->
sign indicator (0x2b["+"] or 0x2d["-"])
<ETX> end-transmit character (0x03)
Note: Checksum is calculated by adding each byte in the message (including all characters from <STX> up to and
including the error log/reason indicator), such that carries are discarded to give a one byte result. The ASCII-coded
decimal representation of that byte is given, ranging from 0 (0x30, 0x30, 0x30) to 255 (0x32, 0x35, 0x35).
Summary of Contents for GNS 530W
Page 2: ...500W Series Installation Manual 190 00357 02 Rev D...
Page 130: ...Page 7 4 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 132: ...Page 8 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 134: ...Page A 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 136: ...Page B 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 137: ...500W Series Installation Manual Page C 1 190 00357 02 Rev D Appendix C RESERVED...
Page 138: ...Page C 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 148: ...Page E 6 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 150: ...Page F 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 160: ...Page G 6 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 162: ...Page H 2 500W Series Installation Manual Rev D 190 00357 02 This Page Intentionally Left Blank...
Page 188: ...Page H 28 500W Series Installation Manual Rev D 190 00357 02 Figure H 16 GTX 330 Interconnect...
Page 194: ...Page H 34 500W Series Installation Manual Rev D 190 00357 02 Figure H 20 RMI OBI Interconnect...
Page 198: ...Page H 38 500W Series Installation Manual Rev D 190 00357 02 Figure H 24 TAWS Interconnect...
Page 211: ...500W Series Installation Manual Page H 51 190 00357 02 Rev D Figure H 33 Switches Interconnect...
Page 215: ......
Page 216: ......