Figure 3-6. Altimeter Interface
When a baro potentiometer is installed, calibrate it as follows:
1.
Press the
CAL
line select key. The calibration page shown in Figure 3-7 will then be displayed. If the
CAL
line select key is pressed when the baro pot is set to NOT INSTALLED, it will automatically be
changed to INSTALLED.
2.
Follow the instructions on the display for calibrating the baro potentiometer. If the GNS 480 will not
accept the calibration when the
MENU/ENTER
key is pressed, there may be a problem with the baro
potentiometer interface.
NOTE
The accuracy of the system is dependent on this calibration. Do not rush this step.
3.
After successfully calibrating the baro potentiometer a green CALIBRATION PASSED message will
be displayed. After this message appears, rotate the baro potentiometer and ensure that the
CURRENT BARO value being displayed is within
±
0.03 "Hg (±1 mB) of the actual altimeter setting.
Figure 3-7. Baro-Altimeter Calibration
Summary of Contents for GNS 480
Page 1: ...GNS 480 CNX80 Color GPS NAV COM Installation Manual November 2008 560 0982 01 Rev L...
Page 10: ...Table of Contents viii 560 0982 01 Rev L GNS 480 CNX80 Installation Manual Notes...
Page 32: ...General Information 1 22 560 0982 01 Rev L GNS 480 CNX80 Installation Manual Notes...
Page 80: ...Installation Procedures 2 48 560 0982 01 Rev L GNS 480 CNX80 Installation Manual Notes...
Page 134: ...Periodic Maintenance 6 2 560 0982 01 Rev L GNS 480 CNX80 Installation Manual Notes...
Page 158: ...Appendix D Interconnect Diagrams D 2 560 0982 01 Rev L GNS 480 CNX80 Installation Manual Notes...
Page 192: ...D 36 560 0982 01 Rev Notes...
Page 199: ......
Page 200: ......