Part # 4517124 Rev. 7 (08/17/11)
Page 26
5. Press five, (5), times. “PROBE CAL – UPPER XXXF” is
displayed.
6. Use or to change the Probe Calibration to the
correct temperature measured with a pyrometer.* SEE
CALIBRATION REQUIREMENTS and CALIBRATION section.
7. Press to save the changes.
8. Press to return to “PROGRAMMING MODE SYSTEM
SETUP”
9. Press again to exit.
To Change Probe Calibration - Grill:
1. Press and hold for three, (3) seconds. “ENTER CODE” is
displayed.
2. Using the Product buttons, 0-9 enter the code, (1251).
“ENTER CODE **** ” is displayed.
3. Press to enter the Programming Mode.
“PROGRAMMING MODE MENU ITEMS” is displayed.
4. Press two, (2) times. “PROGRAMMING MODE SYSTEM
SETUP” is displayed.
5. Press six, (6), times. “PROBE CAL – GRILL XXXF” is
displayed.
6. Use or to change the Probe Calibration to the
correct temperature measured with a pyrometer.* SEE
CALIBRATION REQUIREMENTS and CALIBRATION Section.
7. Press to save the changes.
8. Press to return to “PROGRAMMING MODE SYSTEM
SETUP”
9. Press again to exit.
*CALIBRATION REQUIREMENTS
The control software will beep to the user when it is
appropriate to calibrate. The control will allow calibration
provided the following conditions are met:
• Temperature is currently falling from a detected peak
of 360°F or higher.
• Temperature is falling and has fallen 2°F from a
detected peak that is within the 350-360°F range. (i.e.
calibration would be allowed at 355°F if the achieved
peak temperature was 357°F)
• Temperature is rising through the 350-360°F range as a
result of a heat on pulse of less than 30 seconds.
To Change Platen Top Set:
1. Press and hold for three, (3) seconds. “ENTER CODE” is
displayed.
PROGRAMMING
continued
2. Using the Product buttons, 0-9 enter the code, (1251).
“ENTER CODE **** ” is displayed.
3. Press to enter the Programming Mode.
“PROGRAMMING MODE MENU ITEMS” is displayed.
4. Press two, (2) times. “PROGRAMMING MODE SYSTEM
SETUP” is displayed.
5. Press nine, (9) times. “PLATEN GAP SET +/- XX” is
displayed. (numbers will vary by grill)
6. Use and to change the Platen Gap Set to the
correct value.
7. Press to save the changes.
8. Press to return to “PROGRAMMING MODE MENU
ITEMS”
9. Press again to exit.
To Change Instant-On Time:
1. Press and hold for three, (3) seconds. “ENTER CODE” is
displayed.
2. Using the Product buttons, 0-9 enter the code, (1251).
“ENTER CODE **** ” is displayed.
3. Press to enter the Programming Mode.
“PROGRAMMING MODE MENU ITEMS” is displayed.
4. Press two, (2) times. “PROGRAMMING MODE SYSTEM
SETUP” is displayed.
5. Press ten, (10) times. “INSTANT ON TIME XX:XX” is
displayed. (numbers will vary by grill).
6. Use and to change the Instant on Time to the
desired value.
7. Press to save the changes.
8. Press to return to “PROGRAMMING MODE MENU
ITEMS”
9. Press again to exit.
To Change Control Type:
Note: this must be verified if the control is changed, match
the new control to the grill.
1. Press and hold for three, (3) seconds. “ENTER CODE” is
displayed.
2. Using the Product buttons, 0-9 enter the code, (1251).
“ENTER CODE **** ” is displayed.
3. Press to enter the Programming Mode.
Summary of Contents for XG36
Page 36: ...Part 4517124 Rev 7 08 17 11 Page 36 WIRING DIAGRAMS...
Page 37: ...Part 4517124 Rev 7 08 17 11 Page 37 WIRING DIAGRAMS...
Page 38: ...Part 4517124 Rev 7 08 17 11 Page 38...
Page 39: ...Part 4517124 Rev 7 08 17 11 Page 39...
Page 40: ......
Page 41: ......
Page 42: ...Pi ce n 4517124 Rev 7 08 17 11 Page 39...
Page 43: ...Pi ce n 4517124 Rev 7 08 17 11 Page 38 SCHEMA DE CABLAGE...
Page 44: ...Pi ce n 4517124 Rev 7 08 17 11 Page 37 SCHEMA DE CABLAGE...