7.2
Error messages
LED8
LED7 LED6 LED5
Code Signification
--
--
--
--
--
No mistake, normal function
--
--
--
on
1
No coil current, Hardware overcurrent
--
--
on
--
2
High coil current, Software overcurrent
--
--
on
on
3
Temperature heat sink
--
on
--
--
4
Temperature heating area
1)
--
on
--
on
5
Potentiometer line break
--
on
on
--
6
Temperature inside
--
on
on
on
7
Heating area coil sensor
2)
on
on
--
--
12
Power reduction heat sink temperature
3)
on
on
--
on
13
Power reduction coil temperature
3)
1)
The induction unit can only be startet again if the fault has been given receipt for (turn
power rotary knob „off“)
2)
The induction unit continues working but the temperature of the cooking platform is not
controlled anymore.
3)
The induction unit continues working with reduced power cycles.
„Code“ informs about the number of flashes of the indicator lamp.
Order of error message: The indicator lamp flashes for an interval of 0,6 sec. The number of the
following short flashes has to be counted and informs about the kind of error corresponding to the
above mentioned code system