background image

Document #  G_GHD_OM_PASTACUISINE_4607873 – 08/21

16

PREVENTIVE MAINTENANCE Continued

 6.  To adjust the burner gas pressure, remove the cap from 

the gas valve regulator and use a flat tipped screwdriver 

to adjust the regulator to obtain the correct pressure.

 

7.  Place the power switch and the gas valve in the 

OFF

 

position.  Remove the fitting from the pressure tap hole 

and reinstall the pressure tap plug.

Measuring Flame Current

When the burner flame is properly adjusted, it will produce 

a current between 2.5 μA and 3.5 μA.  Flame current is 

measured by placing a microamp (not milliamp) meter in 

series with the white sensing wire on one of the ignitors.  This 

is accomplished as follows:

1.  Place the power switch in the 

OFF

 position.

2.  Disconnect the sensing wire from one of the burner 

ignitors and connect it to the positive lead of the meter.  

Connect the negative lead of the meter to the terminal 

from which the sensing wire was removed.

3.  Place the power switch in the 

ON

 position to light the 

burners.  After the cookpot temperature reaches 2000F 

(930C), wait at least one minute before checking the 

reading.  

NOTE

: The closer the unit is to normal operation 

temperature, the more accurate the reading will be.

Controller Simmer Mode Adjustment

NOTE:

  The controller simmer temperature is adjustable 

from 185°F to 215°F (85°C to 102°C).  There are two versions 

of this controller; one is adjusted by programming, the 

other is manually adjusted.  To determine which version of 

the controller you have, turn the controller off by pressing 
the power 

switch.  The display will go blank.  Press the 

Simmer Mode 

(right thermometer icon) switch.  

CODE

 

appears in the display.

1.  Press 1, 6, 5, 0 to enter the programming mode.  The 

currently programmed simmer setpoint will be displayed.  

If the setpoint is 

not correct

, enter the desired setpoint 

(for example, press 2, 0, 0 to program the simmer setpoint 

to 200°).

2.  Press the Simmer Mode 

switch again to lock the 

setpoint, then press the power 

switch to turn the 

controller on and return to the normal operating mode.  

Summary of Contents for PASTA MAGIC

Page 1: ...nd web site at http www garland group com The information contained herein including design and parts specifications may be superseded and is subject to change without notice WARNING IMPROPER INSTALLA...

Page 2: ...BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL INC BOCA AND THE FOOD SERVICE SANITATION MANUAL OF THE FOOD AND DRUG ADMINISTRATION GARLAND PASTA COOKERS EQUIPPED WITH LEGS ARE FOR PERMANENT...

Page 3: ...eparations 7 Connection to Gas Line 8 Converting to Another Gas Type 9 Operating Instructions 10 Finding Your Way Around the Pasta Cooker 10 Controller 11 Operating Instructions 12 Start up Procedure...

Page 4: ...n addition to the model number serial number and type of gas please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your...

Page 5: ...gas fired appliances Qualified personnel must be experienced in such work be familiar with all gas precautions involved and have complied with all requirements of applicable national and local codes...

Page 6: ...s defined in Section 1 5 of this manual should perform all installation and service on Garland equipment Conversion of this appliance from one type of gas to another should only be performed by qualif...

Page 7: ...cooker door Connect a cooker only to the type of gas indicated on the rating plate Installation shall be made with a gas connector that complies with the national and local codes or regulations in fo...

Page 8: ...egulatory agency of the country in which the appliance is installed 4 For units equipped with basket lifts install the basket lift arms onto the rods located at the top rear of the cabinet to ensure t...

Page 9: ...ng to Another GasType DANGER Your cooker is configured at the factory for a specific type of gas If you desire to switch from one type of gas to another specific gas conversion components must be inst...

Page 10: ..._PASTACUISINE_4607873 08 21 10 OPERATING INSTRUCTIONS FindingYourWay Around the Pasta Cooker Overflow Low water sensor High water sensor Temp probe Drain Cook pot Trouble light Controller Drain valve...

Page 11: ...ces the efficiency of the cooker and can cause erroneous temperature and water level sensing NOTE Do not use deliming solution to clean these units Use of deliming solution will damage all stainless s...

Page 12: ...hould display a bright orange red glow If a blue flame is observed or if there are dark spots on a burner face the air gas mixture requires adjustment as explained below NOTE Adjusting the Air Gas Mix...

Page 13: ...r turn the unit off and add cold water until the solution is cool Drain the solution and clean the cookpot thoroughly with a solution of dishwashing detergent and hot water 5 Rinse the cookpot at leas...

Page 14: ...water and or food products Clean Water Level Sensors Temperature Probe Cookpot and Rinse Tank 1 Turn the equipment off and drain the cookpot and rinse tank if so equipped 2 Remove the probe cover and...

Page 15: ...display a bright orange red glow If a blue flame is observed or if there are dark spots on a burner face the air gas mixture requires ad justment On the side of the blower housing opposite the motor...

Page 16: ...sing wire was removed 3 Place the power switch in the ON position to light the burners After the cookpot temperature reaches 2000F 930C wait at least one minute before checking the reading NOTE The cl...

Page 17: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 17 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 18: ...the Welbilt KitchenCare HOTLINE 844 724 2273 Verify that electrical cords are plugged in and that circuit breakers are on Verify that water supply valves are open and that the drain valves are fully c...

Page 19: ...es not sense sufficient water in the cookpot it will not allow the burners to fire B Remove the probe block cover and clean the sensors using a Scotchbrite or similar pad and a solution of detergent a...

Page 20: ...oller If the AUTOFILL functions correctly the only cause possible is a failed controller A Order replacement controller from FASC or distributor WATER WILL NOT BOIL Cookpot verified to be full of wate...

Page 21: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 21 Notes...

Page 22: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 22 Notes...

Page 23: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 23 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 24: ...therm Crem Delfield fitkitchen Frymaster Garland Kolpak Lincoln Manitowoc Merco Merrychef and Multiplex Bringing innovation to the table welbilt com 2021 Welbilt Inc except where explicitly stated oth...

Reviews: