INPUT SPECIFICATIONS
(continued)
SUPPLY
TOTAL
kW
LOAD
NOMINAL AMPS PER LINE
208V / 60Hz
220V / 60Hz
240V / 60Hz
L1
L2
L3
L1
L2
L3
L1
L2
L3
INPUT 1
11.2kW
31.0
31.0
31.0
29.5
29.5
29.5
27.0
27.0
27.0
GAS INPUT
GAS
MAX INPUT
(NET) PER
BURNER
(BTU/H)
TOTAL INPUT
RATING
(BTU/H)
INJECTOR
SIZE
AIR SHUTTER
SETTING
(*)
SUPPLY
PRESSURE
(IN W.C.)
BURNER
MANIFOLD
PRESSURE
(IN W.C.)
NATURAL GAS
32,000
64,000
#35
50%
7.0
3.5
PROPANE
32,000
64,000
1.75mm
50%
11.0
10.0
Input Specifi cations, GAS Grills, 2 Platen MWG2W North America:
ELECTRICAL REQUIREMENTS: 3N~ 50Hz (3 Phase + N , 4-wire)
TOTAL
kW
LOAD
LOADING: (kW/PHASE)
NOMINAL AMPS PER LINE
380V / 400V / 415V
380V
400V
415V
L1/N
L2/N
L3/N
L1
L2
L3
L1
L2
L3
L1
L2
L3
INPUT 1
9.8
3.3
3.3
3.3
14.9
14.9
14.9
14.2
14.2
14.2
13.6
13.6
13.6
GAS INPUT
GAS GROUP
MAX INPUT
(NET) PER
BURNER (kW)
TOTAL INPUT
RATING (kW)
INJECTOR
SIZE
AIR SHUTTER
SETTING (mm)
(*)
SUPPLY
PRESSURE
(mbar)
BURNER
PRESSURE
(mbar)
VOLUMETRIC
GAS RATE
G20 NG
8.6
17.2
2.64mm
9.0
20/25
8.7
1.82m
3
/h
G31 LPG
8.6
17.2
1.61mm
9.0
37/50
24.9
1.34kg/h
GAS CATEGORIES
CATEGORY
DESTINATION COUNTRIES
SUPPLY PRESSURE (mbar)
I
2H
AT, CH, CZ, DK, ES, FI, GB, IE, IS, IT, NO, PT, SE
20
I
2E
DE, LU
20
I
3P
NL
30
I
3P
BE, CH, CZ, ES, FR, GB, GR, IE, LU
37
I
3P
BE, CH, DE, CZ, ES, FR, NL
50
(*) NOTE: Air shutter setting may vary by region. Only a qualify service technician should make adjustments
for proper combustion
Input Specifi cations, GAS Grills, 2 Platen MWG2W CE Approved Model: