Page 30 | HEEGM Service Manual part# 4532502 (Rev 0)
6 COMPONENTS
(CONT.)
6.10 Ignition Module
Depending on the model, you will find a 4-spark, a 6-spark, or both types of ignition modules
installed in the Right Leg of the broiler. When energized, the module sparks continuously until
flame is sensed.
6.10.1 Specification
•
Spark voltage for each output/electrode: 25kV.
•
Electrode gap distance: min 0.125in (1/8in), max 0.160in (5/32in).
•
Flame-sensing technique: flame-rectification.
6.10.2 Evaluation
•
Refer to section “5.2 Troubleshooting Flowchart”.
6.10.3 Remove or Install an Ignition Module
WARNING
Disconnect power supply to the unit and allow the unit to cool down.
To remove or install a module:
1.
WARNING: Disconnect power supply to the unit and allow the unit to cool down.
2. Remove the RIGHT Side Leg Panel (see section 6.3).
i
Ensure you pull out the panel slowly to avoid disconnecting any wiring accidentally.
3.
i
Note wire numbers and location before removing all wire connections from the module,
or refer to the wiring diagram.
4. The module is mounted onto a bracket. To separate the bracket from the frame, loosen the
screws on inner side of the right leg.
5. Dismount the module from the bracket.
6. Replace module and reassemble in reverse order.
7.
i
Ensure the connections between the male and female connectors are secured to the main
power line at the back (see “4.3 Major Components Illustrated”).
8.
i
To avoid pinching the wires, tuck the wires safely away before sliding back the Leg Panel.
Summary of Contents for HEEGM48CL
Page 34: ...Page 34 HEEGM Service Manual part 4532502 Rev 0 7 WIRING DIAGRAMS HEEGM24CL 120VAC ...
Page 35: ...Page 35 HEEGM Service Manual part 4532502 Rev 0 7 WIRING DIAGRAMS CONT HEEGM24CL 240VAC ...
Page 37: ...Page 37 HEEGM Service Manual part 4532502 Rev 0 7 WIRING DIAGRAMS CONT HEEGM36CL 240VAC ...
Page 41: ...Page 41 HEEGM Service Manual part 4532502 Rev 0 7 WIRING DIAGRAMS CONT HEEGM60CL 240VAC ...
Page 43: ......