![Garland EFW800 Service Manual Download Page 6](http://html1.mh-extra.com/html/garland/efw800/efw800_service-manual_3604190006.webp)
Part # 4521056 Rev 2(02/21/12)
Page 6
OPERATING INSTRUCTIONS
This appliance requires water in the tank for even heating.
Before fi rst use it is recommended that the inside of the
tank be cleaned with a detergent soaked cloth, to remove
fabricating and protective oils. Rinse with clean water and
dry with a clean cloth.
The EFW800 is a full size 12” x 20” (305mm x 508mm)
capacity fondant warmer. It is designed to maintain fondant
temperature at 115 °F (46 °C). To achieve this, the appliance
heats a water bath slightly higher than the required fondant
temperature.
Operating Procedure
1. Fill the tank with water so that the level is between the
minimum and maximum embossed lines on the inside
wall of the tank.
2. Insert pans with a maximum depth not exceeding 4”
(102mm).
3. Plug appliance into electrical outlet.
4. Turn on the appliance by pressing the switch marked ON
– OFF in the ON position.
5.
Lamp Test: After the control has initialized, the amber
WARNING indicator will illuminate for 10 seconds. This
lets the operator know the lamp is functioning.
6. The appliance will initially heat the bath of water to a
temperature of 145°F (63°C), then maintain it at 122°F, ±3
°F (50°C, ±2 °C). Temperatures are measured with a lid or
pans in covering the tank.
1
2
3
Indicators
1. The power switch is illuminated when the switch is in the
ON position and power is applied to the appliance.
2. The green READY lamp indicates the water bath has
reached its normal operating temperature. Fresh cold
fondant may take longer to heat. See the section Fondant
Heating Hints for more details in the Operating Manual
4521055.
3. The amber WARNING lamp has multiple functions. A
fl ashing WARNING lamp indicates a low water condition. If
the amber lamp is illuminated continuously it indicates a
temperature sensor failure and service personnel should
be contacted.
NOTE: Periodic checks should be made during operation
to ensure that the water level does not fall below the lower
embossed line. Should it do so, top up with fresh
cold
water.
We recommend cleaning the tank and fi lling with clean cold
water to the embossed line after a low water condition.
IMPORTANT: After a low water condition, fi ll with cold
water. Only cold water will reset the fl ashing lamp.
Adding hot water will not reset the low water condition
immediately. The lamp will continue to fl ash if the water
temperature does not drop below 100°F (38°C).
Summary of Contents for EFW800
Page 14: ...Part 4521056 Rev 2 02 21 12 Page 14...
Page 15: ...Part 4521056 Rev 2 02 21 12 Page 15 WIRING DIAGRAM I1 I2 I3 I4 I5 I6 I7 I8 Q2 Q3 Q4 Q1...
Page 16: ...Part 4521056 Rev 2 02 21 12 Page 16 MODEL EFW800 EFW800 PARTS BREAKDOWN...
Page 18: ......
Page 19: ......
Page 21: ...Pi ce n 4521056 Rev 2 02 21 12 Page 16 Mod le EFW800 CLAT DES PI CES DU MOD LE EFW800...
Page 22: ...Pi ce n 4521056 Rev 2 02 21 12 Page 15 SCH MA DE C BLAGE I1 I2 I3 I4 I5 I6 I7 I8 Q2 Q3 Q4 Q1...