![background image](http://html2.mh-extra.com/html/gardner-denver/welch-lvs-600-t/welch-lvs-600-t_operation-manual_5061726020.webp)
Technical Data
20
115051
Parameter
Unit
LVS 610 T ef
LVS 610 T en
Pumping speed 50/60 Hz
DIN 28432
at speed of 1500 rpm
m
3
/ h
4.9
4.5 / 4.9
Ultimate pressure
at speed of 1500 rpm
mbar
2
Ultimate pressure
with gas ballast
at speed of 1500 rpm
9
Max. inlet pressure
bar
1
Max. outlet pressure
1
Intake and pressure ports
-
Hose nozzle DN 8
for hose inside diameter 8 mm
Ambient temperature
°C
+ 10 to + 40
Max. Operating gas
temperature
+
4
0
Bearing
-
maintenance-free
Reference surface
sound pressure level
DIN EN ISO 2151
dB (A)
44
Voltage / Frequency
(different data upon customer
request)
V, Hz
230, 50/60 (115, 50/60)
(generally with motor protection switch, switch and cable)
Motor power
W
370
Input Frequency changer
(Apparent power)
W / A
800 / 6
-
Operating mode
-
S 1
Type of protection
DIN EN 60529
IP 54
Motor / Class of insulation
DIN EN 600034-1
F (160°C)
Type Examination
Certificate no.
-
WELCH_ATEX_03-01
Designation EX
II3G IIC T3 X (internal Atm. only)
Dimensions (W/D/H)
mm
360 / 310 / 445
Weight
kg
26.8
24.7
Order numbers for LVS:
-
230 V
inclusive mains connection cable
IEC with plug CEE, UK
-
LVS …
-
LVS … netvac 1
-
LVS … with built-in controller
VC 521 extern
115254
115254-03
115254-04
115258
-
-
115 V
inclusive mains connection cable
IEC with plug US
-
LVS …
115254-01
115258-01