10. Service and maintenance
43
Fig. 17
1 Oil filter cartridge
The changing intervals can be found in the
maintenance schedule.
Replace the oil filter cartridge as follows:
•
Switch the screw compressor unit off and ensure that
it is depressurized, electrically isolate and locked off.
•
Wait at least 5 minutes for the oil to settle and for
the air to disperse.
•
Unscrew the oil filter cartridge ( - 1 - Fig. 17) using
an appropriate tool
•
Dispose of the oil filter cartridge according to the
regulations
•
Oil the gasket of the new oil filter cartridge slightly
•
Screw on the new oil filter cartridge and tighten
manually (take notice of the instructions on the oil
filter cartridge)
•
Check for leakage
•
Check oil level (see Section 7.5)
•
If required, top up oil.
Changing intervals for oil filter cartridge
The operating conditions (e.g. coolant temperatures),
the operating modes and the quality of the intake air
(e.g. content of dust, content of gaseous foreign matter
such as SO
2
, solvent vapours, etc.) have a strong
influence on the service life of the filters (air filters, oil
filters, fine separators).
Where such conditions exist the filter element may
require changing more frequently.
10.6
Change of the fine separator
cartridge
DANGER
Air/oil under pressure will cause severe
personal injury or death.
•
Shut down the compressor, relieve the
system of all pressure, disconnect,
lockout and tagout the power supply to
the compressor package before
removing valves, caps, plugs, fittings,
bolts and filters.
CAUTION
Fire hazard and slip hazard!
•
Do not spill any oil!
•
Look for leaks! Immediately take care of
any spilled oil!
NOTICE
Dispose of the fine separator properly - it is
hazardous waste! Look for leaks!
Fig. 18
1 Oil fine separator
For the changing intervals, see the maintenance schedule.