![background image](http://html1.mh-extra.com/html/gardner-denver/l15/l15_original-operating-manual_3777380054.webp)
12. Annex
52
12.2
Technical data USA/Canada version L15 RS
Technical data 50Hz / 60Hz
L15 RS
Maximum operating pressure
psi g
186
Minimum operating pressure
psi g
73
Ambient temperature
°F
+ 34 / + 113
Operating pressure
psi g
110
130
145
190
min.
max.
min.
max.
min.
max.
min.
max.
Flow
cfm
32.7
92.0
31.3
85.3
30.5
76.9
29.3
59.1
After-cooler outlet temperature above ambient temp.
°F
20
Sound pressure level (to ISO 2151)
dB(A)
72
Nominal motor rating
hp/ kW
20 / 15
Voltage (frequency)
V
460V[+/-10%] (60 Hz)
Full-load current max. at 460V
Amps
37
Motor protection type
TEFC (IP55), EPAct
Nominal speed
rpm
1146 … 2950
Nominal fan motor power
no separate fan motor
Recommended cable size at 460V ; @ 167 °F
AWG
AWG 8
Recommended fuse rating at 460V, time delay
Amps
50
Cool air exhaust temperature above ambient temp.
°F
36
max. allowable pressure drop in duct at ambient
Pa
30 / 20
Total oil volume
gal (Litres)
2.5 (9.5)
Compressed air delivery connections
–
1 - 11 1/2 NPT
Weight
lbs (kg)
805 (365)
Dimensions L x W x T
inch (mm)
31 x 27.5 x 47.3 (787 x 698 x 1202)