13-8-638 Page 44
SYMPTOM
POSSIBLE
CAUSE
REMEDY
3.
Shaft seal leaking.
3.
Replace shaft seal.
Oil carryover
1.
Overfilling the reservoir.
1.
Drain excess oil from
system.
2.
Clogged, broken or loose
oil return lines.
2.
Tighten or replace faulty
lines.
3. Ruptured
oil
separator
element.
3. Replace
element.
4.
Loose assembly.
4.
Tighten all fittings and
gaskets.
5.
Foam caused by use of
incorrect oil.
5. Use
Gardner
Denver
AEON 2000, 4000 or
9000SP lubricating
coolant.
6. Inoperative
minimum
pressure valve.
6.
Replace seals in valve.
7.
Operation at elevated
discharge temperatures.
7.
Reduce temperature. See
“High Discharge Air
Temperature”, this
section.
8.
Scavenge line check valve
failure.
8.
Replace check valve.
9.
Water condensate in oil.
9.
Check oil reservoir
temperature and if low,
change thermal mixing
valve element to higher
temperature.
DANGER
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters
Summary of Contents for INTEGRA EFD99B
Page 9: ...13 8 638 Page 2 Figure 1 2 COMPRESSOR ILLUSTRATION 300EFD797 A Ref Drawing...
Page 12: ...13 8 638 Page 5 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 13: ...13 8 638 Page 6 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Page 29: ...13 8 638 Page 22 Figure 4 3 WIRING DIAGRAM FULL VOLTAGE 303EFD546 D Ref Drawing Page 1 of 2...
Page 30: ...13 8 638 Page 23 Figure 4 4 WIRING DIAGRAM FULL VOLTAGE 303EFD546 D Ref Drawing Page 2 of 2...