13-8-638 Page 41
MAINTENANCE SCHEDULE (See Detail Notes above)
Maintenance Action
As Indicated by
AutoSentry
Controller
Every 8
Hours
Every
125
Hours
Every
1000
Hours
Every
4000
Hours
Every
Year
Check/Change Air Filter .....................................................
•
Change Oil Separator .......................................................
•
•
Check Reservoir Oil Level ** ..............................................
•
Check for Proper Load/Unload...........................................
•
Check Dirt Accumulation on Cooler ...................................
•
Change Oil Filter Element & Clean Oil Return Strainer .....
•
Change Compressor Lubricant (AEON 4000) * .................
•
Check Relief Valve .............................................................
•
Check Condition of Hoses..................................................
•
•
Change Inlet Valve Seals ...................................................
•
* See “Oil Change Interval Chart”, Figure 5-3, page 26, for specific lubricant life.
** Must be checked when the compressor is stopped and the air/oil mixture is separated.
Summary of Contents for INTEGRA EFD99B
Page 9: ...13 8 638 Page 2 Figure 1 2 COMPRESSOR ILLUSTRATION 300EFD797 A Ref Drawing...
Page 12: ...13 8 638 Page 5 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 13: ...13 8 638 Page 6 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Page 29: ...13 8 638 Page 22 Figure 4 3 WIRING DIAGRAM FULL VOLTAGE 303EFD546 D Ref Drawing Page 1 of 2...
Page 30: ...13 8 638 Page 23 Figure 4 4 WIRING DIAGRAM FULL VOLTAGE 303EFD546 D Ref Drawing Page 2 of 2...