Decommissioning
11
© Gardner Denver Deutschland GmbH
39
/
44
08.2019 · 610.44434.40.000
Decommissioning
Decommissioning
DANGER
Lethal electric shock from G-BH1 | G-BH9 with drive control!
The drive control continues to be live after the intermediate circuit voltage
has been switched off and slowly becomes de-energised.
1. After switching off, wait for
at least 3 minutes
.
2. Before opening the drive control, ensure that it is de-energised.
!
The G-BH1 | G-BH9 can remain in the unit or be dismantled for storage.
1. Disconnect the G-BH1 | G-BH9 from the power supply.
2. Depressurise the pipes.
Disassembly
1. Disconnect the G-BH1 | G-BH9 from all electrical connections.
2. Dismantle the piping and hoses.
3. Close connections that are open.
4. Loosen the G-BH1 | G-BH9 from the installation surface.
5. Store [
➙
20] or dispose of [
➙
39] G-BH1 | G-BH9.
Disposal
WARNING
Burns, chemical burns or poisoning!
Risk of injury due to contact with residual hazardous substances in the G-
BH1 | G-BH9.
Decontaminate the G-BH1 | G-BH9 as instructed by the manufacturer of the
hazardous substances.
1. Remove the G-BH1 | G-BH9 according to the repair manual [
➙
6].
2. Collect solvents, residual lacquer and grease and dispose of them in accord-
ance with the valid local regulations.
3. Dispose of components according to the valid local regulations or recycle
them.
11
11.1
11.2
11.3
Summary of Contents for Elmo Rietschle 2BH11