System Overview
Area Codes (Controlling Specific Areas)
Cleaner
(Area 0)
Area 1
Area 2
Area 3
Main Area 1
Main Area 2
Main Area 3
These area codes will only control their specific areas. Area codes are 'low level codes'
and have no user options, they will however allow for the part setting of each area.
Areas 1 to 3 may have up to 3 part sets suites (groups of zones). If part set 1 is used
zones programmed into the part 1 suite will be removed (omitted), if part set 2 is used
zones programmed into the part 2 suite will be removed and if part set 3 is used zones
programmed into both part 1 and part 2 suites will be removed.
It should be noted that the zones programmed into a part set suite are programmed by
the engineer and not the user.
To set an area simply enter the required area code (Press YES if a Main Area Code is
used) and exit the area.
To part set an area enter the area code followed by NO and the part set number
required (1, 2 or 3). If Main Area type code is used enter code followed by part set
number.
To unset an area enter the area code.
Cleaner Code (part set 0)
The Cleaner code or part set 0 acts in a different way to the other area codes. To set
the system and remove the cleaner zones start to set the system followed by YES 0
This will set the system or area and remove the cleaner zones.
If a cleaner code is now entered the cleaner zones will also be set.
If a cleaner code is entered when the system is fully set or area set only the cleaner
zones will be unset.
It should be noted that any entry/exit zones that are removed or unset via the cleaner
code or part set 0 will chime when violated. This is to prevent other users straying into
protected areas without warning.
More details of codes and using the system are given in the relevant sections of this
manual, and in the user manuals.
Page
5
2
S
YSTEM
O
VERVIEW
Codes
The Gardtec
840
is capable of accepting up to 47 user codes (7 for
800/816
) plus 1
engineer code. Each of the user codes is allocated a code type (with the exception of
user 1 that is always Master) at the time the code is programmed. Ten code types plus
engineer are available, these are:-
Type Number
Code Type (
840
)
Code Type (
800/816
)
0
Set Only
1
Main
Set Only
2
Area 1 User
Main
3
Master User
4
Cleaner
Master
5
Area 2 User
Cleaner (816 only)
6
Area 3 User
Duress (816 only)
7
Main Area 1
8
Main Area 2
9
Main Area 3
Note 1: User 1 will always be Master.
Note 2: 800/816 have no area facilities.
A full list of options that are available for the code types are given in the user manual.
As a general guide for this section the codes for the Gardtec
840
are split into two
groups, Global and Area codes. Codes allocated to these groups are as follows:-
Global Codes (Controlling All Areas).
Master
Main
Set Only
Engineer
If any area is set, entering a global code (not Set Only or Cleaner) will unset all areas
If all areas are unset, entering a global code followed by YES (or code then NO YES if
Engineer code is used) will give the option to set all areas.
The global codes with the exception of Set Only also have other options. More details
of these options are given in the user manual.