Page
59
Page
58
GARDTEC
800 Series
Programming
Option No/
Description
Default
Gardtec
800 Series Programming Guide
Available Options
45
Internal
Sounder
Mode
Constant
(00)
(00) Constant
(01) Timed
Note: The term Internal Sounder refers to the Speaker Output
46
[Area1]
Alarm
Reset
Master
Code
(01)
(00) Any Code
(01) Master Code
(02) Anti-Code
(03) Engineer Code
(04) En Anti-Code
(05) Main Code
47
Tamper
Reset
Any
Code
(00)
(00) Any Code
(01) Master Code
(02) Anti-Code
(03) Engineer Code
(04) En Anti-Code
(05) Main Code
48
Backlight
Mode
On in
E/E or if
Keypress
(02)
(00) Off
(01) On If Key pressed
(02) On In E/E or if Keypressed
(03) Always On
49
Zone
Re-Arm
On
(01)
(00) Off
(01) On
Note: This option determines zone rearm after an alarm
50
Onboard
Zone
Wiring
8 (4 Wire)
(00)
(00) 8 (4 Wire)
(01) 16 (EOL)
(02) 16 (2 Wire)
Note: Refer to options 72, 75 & 76 for programming Zone Expanders &
Zone Expander Wiring Modes for 816 & 840
51
Zone Types,
Zone
Remove,
Zone
D/Knock
Enter zone
No. followed
by YES to
gain access
to zones.
When
finished use
0 to escape
Zone1
E/E
Non-Rem
Zone2
Access
Non-Rem
Z1 (11)
Z2 (21)
All
Others
12Hr
Non-Rem
(01)
(Left Digit LED)
(Right Digit LED)
(0) 12Hr
(0) Removable
(1)Entry/Exit
(1) Non-Removable
(2) Access
(2) Removable D/Knock
(3) Panic
(3) Non-Removable D/Knock
(4) 24Hr
(4) Off
(5) Fire
(5) Normal Key Zone
(6) Alert
(6) Biased Key Zone
(7) Exit Terminator Button
(8) Part Entry/Exit
(9) Monitor
Note: Expansion wiring needs to be programmed first via option numbers 72 to 82
Note: Refer to option 52 for zone attributes.
Note: Refer to option 71 for Area and Chime attributes.
52
Test/
Part Sets/
Cleaner
Off Test
(00)
(Left Digit LED)
(Right Digit LED)
(0) Full Set
(0) Off Test
(1) Part 1 Set
(1) On Test
(2) Part 2 Set
(3) Part 3 Set (Parts 1&2)
Prompt for LED is n- Enter zone
(4) Full Set + Cleaner
No YES then setting YES
(5) Part 1 Set + Cleaner
(6) Part 2 Set + Cleaner
For LED Chime & FWT is via
(7) Part 3 Set (1&2) + Cleaner
option 71
For LCD screens press NO to initial screen, then enter zone No followed by YES or
NO to add or remove zone in Test or Part screens.
GARDTEC
800 Series
Programming
Option No/
Description
Default
Gardtec
800 Series Programming Guide
Available Options
34
Digi Type
Normal
(02)
(00) None
(01) Gardiner
(02) Normal
(03) Mod+FF
(00) None
(01) Gardiner
(02) Normal
(03) Mod+FF
(04) Mod+PID
(00) None
(01) Gardiner
(02) Normal
(03) Point ID
(04) Mod+PID
(05) Mod+FF
Note: In all cases. Factory fitted link between 12V & Linefault terminals must
be removed if Modem or ProDigi is being used or programmed.
35
Key Beep
Volume
Activations
(05)
00 - 09
36
Multi
Keypad
Off
(00)
(00) Off
(01) On
Turn this option On when more than 4 keypads are used
37
D/Knock
Time
Window
01
Minutes
(01)
00 - 99 Minutes
38
Engineer
Code
1234
(1234)
4 - 6 Digits
39
Remote
Reset
Off
(00)
(00) Remote Reset Off
(01) Remote Reset On
Note: If Remote reset is used in conjunction with RedCare the Remote
Reset line to the panel should be connected to Line Fault source terminal
that has been selected via option 127
40
Linefault
Sounders
Always
Off
(01)
(00) 24Hr
(01) Always Off
(02) On If Set
(03) On If Unset
(04) FLT If Off
(05) Beep If Off
Note: If Modem or ProDigi is used on shared line program Linefault
Sounders to On If Set or Off.
41
Linefault
In Exit
Ignore
In Exit
(01)
(00) Detect In Exit (01)Ignore In Exit
Note: Detect In Exit will prevent setting of system if a Linefault is present.
Ignore In Exit will only warn.
42
Linefault
Log
Limited
(01)
(00) Off
(01) Limited
(02) Exit/Set
43
Duress
Mode
On
(01)
(00) Off
(01) On
44
Sensor
Output
Mode
Pulse
Off
(00)
As Output Expander Modes (Option 83)
Note: The term Sensor Output refers to the DET RESET terminal.
4344R12.qxd 03/09/99 11:09 Page 58