Printer Connection
The Gardtec
816/840
has an RS232 port that may be connected to a standard serial
printer, to facilitate this two printer leads are available from Gardiner Technology.
Printer Cable No. 1
Part No 01-091
Connects from PCB direct to printer
Printer Cable No. 2A
Part No 01-092
Connects from PCB to chassis mounting
DIN socket (to be mounted on panel
case).
Printer Cable No. 2B
Part No 01-093
DIN plug to printer
The printer should be capable of being set to the following:-
Baud Rate
1200
Data Bits
8
Parity
None
Stop Bits
4
Carriage Return
None
Note:
The printer should have its own power supply. Under no circumstances
should the power for the printer be drawn from the control panel.
The printer may be used in one of three modes:-
1)
For printing the Event Log (user or engineer function). Pressing 1 whilst
viewing the Event Log will start the printer (refer to user manual for more
details).
2)
For printing the Program Review (engineer function). Pressing 1 whilst in the
engineer option Program Review will start the printer.
3)
For Real Time Printing. When Real Time Printing is programmed to ON each
event that is written to the log will also be sent to the printer.
This option needs to be set ON from within the engineer programming mode
(option 96) and may be overridden by the user by using the online/offline
function on the printer.
GARDTEC
800 Series
Wiring Connections
Engineers RKP Connection
To aid installation and programming an Engineers LCD RKP is available (part No. 02-
069) that may be plugged directly onto the main PCB of the control panel. The
engineers RKP may be configured as RKP 1 to 4 and will be supplied from the factory
as RKP1. In this configuration it will work in tandem with RKP 1 on the system. It
should be noted that if the system RKP1 is a keypad with twin seven segment LED
display the engineers RKP will need to be reconfigured to an unused ident or one that
is occupied by an LCD RKP.
The engineers RKP should be connected to the plug on the main PCB marked SK2
ENG RKP. The connector is 'keyed' and will only fit in one orientation, the use of force
should be avoided to prevent damage to the plug/socket.
GARDTEC
800 Series
Wiring Connections
4344R12.qxd 03/09/99 11:09 Page 48