background image

13

G

12

G

Over-wintering :

Note :

Do not use any hard objects or powerful detergents for cleaning
the set ! 

Remove dirt deposits in the pump :

1. Unplug the water fountain pump from the mains.

2. Remove the filter set from the pond.

3. Pull hose 

3

off the pump and unscrew threaded sleeve 

7

.

4. Open up pump filter housing 

8

and remove the pump.

5. Open the snap hook 

b

and  take the pump cover 

9

off the

motor housing 

A

.

6. Draw the impeller unit 

0

out of the motor housing 

A

.

7. Remove any dirt deposits from pump components.

8. Replace the impeller unit 

0

in the motor housing 

A

.

9. Press the pump cover 

9

into the motor housing 

A

until the

connection is heard to snap into place.

6. Trouble-Shooting 

Fault 

Possible Cause 

Remedy 

The water is not clear.

The pond is extremely dirty 

1. Check nitrate concentration 

and rich in nutrients.

(e. g. with the GARDENA 
Pond Test Set, Art. No.
7920) 

2. If necessary, change the 

water and clean the pond 
liner.

Too many fish and creatures 

v

Add up the estimated length 

in the pond.

of the fish.

There should only be “80 cm 
fish” per m

3

water in the pond.

Pump does not work.

Connections are faulty.

v

Check connections.

Impeller unit blocked.

v

Remove dirt deposits in the 
pump (see 5. Maintenance).

If any other faults arise, please contact GARDENA Service.

7. Putting out of Operation 

1. Before frosts commence, remove the Filter Set from the pond,

take the hose off the pump and empty the filter completely.

2. Clean the Filter Set.

3. Store the filter in a frost-proof place.

4. Store the pump in a container full of water, in a frost-free place.

The mains plug should not be soaked during the process.

Store out of reach of children.

A

9

b

0

Do not allow the pump to run without water :

Do not allow the pump to run without water because dry-running
leads to an undesirable build up of heat and will destroy the
pump.

The water throughput quantity for the filter and therefore the 
height of the fountain can be set to any desired level.
The more water flowing through the filter, the less flows through
the fountain and vice versa.

v

Hold the T-piece

firmly and turn the extension pipe 

1

by hand.

Turn the marking 

a

on the extension pipe 

1

clockwise 

to increase the water throughput for the fountain 

– or – 

turn the marking 

a

on the extension pipe 

1

anti-clockwise 

to increase the water throughput for the filter.

5. Maintenance 

We recommend cleaning the Zeolith inside (approx. 2.5 l) about
every 6 months (e.g. in salt water) or replacing it to ensure that
the zeolith is working properly. Only use 

GARDENA Zeolith  1 l : Art. No. 7914 

Zeolith  5 l : Art. No. 7915 
Zeolith 10 l : Art. No. 7913

when replacing the filter.

1. Unplug the fountain pump from the mains.

2. Remove the filter set from the pond.

3. Remove the hose 

3

from the pump.

4. Take the filter cover 

6

off.

5. Empty the filter container 

4

completely and rinse out.

6. Remove the Zeolith net 

5

and soak for approximately 

24 hours in a solution of cooking salt (20 g salt / litre).

7. Then rinse the Zeolith net 

5

with fresh lukewarm water.

8. Assemble the filter again in reverse order.

9. Start the filter up again (see 4. Putting into Operation :

“Using the filter for the first time” ).

Cleaning the pump filter housing :

The water intake slots on the water feature pump must be free
from dirt.

1. Unplug the fountain pump from the mains.

2. Remove the filter set from the pond.

3. Pull hose 

3

off the pump and unscrew threaded sleeve 

7

.

4. Open up the pump filter housing 

8

and spray clean with 

a jet of water.

5. Clean the water intake slots of the filter housing 

8

with 

a brush.

Setting the water throughput
quantity :

Cleaning the filter :

Cleaning the pump :

3

4

5

6

7

8

a

1

T

T

www.devicemanuals.eu

Reviews: