background image

4. MAINTENANCE

  

DANGER! Risk of injury!

 

Injury when the product starts accidentally.

 Disconnect the product from the mains before 

you maintain the product.

To flush the pump:
After pumping chlorinated water, the pump must be 

flushed.
1. Pump lukewarm water (max. 35 °C), possibly adding 

a mild cleaning agent (e. g. detergent) until the pumped 

water runs clear.

2. Remove residuals according to the waste disposal laws 

applicable in your area.

5. STORAGE

To put into storage: 
The pump is not frost-proof!
The product must be stored away from children.

1. Disconnect the pump from the mains.
2. Turn the pump upside down until no more water runs 

out.

3. Clean the pump (see 4. MAINTENANCE).
4. Store the pump in a dry, enclosed and frost-free place.

Disposal:

(in accordance with RL2012/19/EC)

The product must not be disposed of to normal 

household waste. It must be disposed of in line 

with local environmental regulations.

IMPORTANT!

v  

Dispose of the product through or via your municipal 

recycling  collection centre.

6. TROUBLESHOOTING

  

 DANGER! Risk of injury!

 

Injury when the product starts accidentally.

v  

Disconnect the product from the mains before 

you troubleshoot the product.

To clean the suction base and the impeller [ Fig. T1 ]:
1. Unscrew the 4 Phillips screws 

(4)

.

2. Pull the suction base 

(5)

 off the pump.

3. Clean suction base 

(5)

 and impeller 

(6)

 (the warranty 

does not become void as a result of this maintenance 

work).

4. Reinstall the suction base 

(5)

.

5. Screw in the 4 Phillips screws 

(4)

 again.

For safety reasons a damaged impeller can only be 

exchanged by the GARDENA Service Centre.

Problem

Possible Cause

Remedy

Pump is running, but  

doesn’t deliver water

Air cannot escape, because the 

 pressure line is closed. (Pos sible kink  

in the pressure hose.)

v  

Open the pressure line (e. g. shut-off 

valve, delivery units).

Air in suction foot.

v  

Wait for about 60 seconds until  

the pump has vented; if necessary, 

turn off and then on again.

Suction opening is clogged.

v  

Clean the suction opening with 

a water jet.

Hose is clogged.

v  

Remove the clog from the hose.

Impeller is blocked.

v  

Clean the impeller.

Water level below minimum water  

level when put into  operation.

v  

Submerge the pump deeper.

Pump does not start, or stops 

 suddenly during operation

Thermal switch has turned the pump 

off because of overheating.

v  

Clean the suction opening. Observe 

the max. media  temperature (35 °C).

No power supply to the pump.

v  

Check fuses and electrical plug 

 connections.

RCD has triggered  

(residual current).

v  

Disconnect the pump and contact 

the GARDENA Service.

EN

14

Summary of Contents for 8600

Page 1: ...8200 Art 9000 8600 Art 9001 9200 Art 9007 10500 Art 9008 EN Operator s Manual Clear Water Submersible Pump Dirty Water Submersible Pump EN...

Page 2: ...A1 2 1 O1 3 A2 y 2 A3 Art 7193 O2 3 A4 Art 7195 y A5 T1 6 5 4 4 3...

Page 3: ...ion and is submerged in water for max submersion depth see 7 TECHNICAL DATA The product is suitable for pumping the following liquids Clear Water Submersible Pump clean to slightly dirty water with a...

Page 4: ...edges Observe the mains voltage The information on the name plate must be in agreement with the data for the mains power grid The pump s mains plug must be disconnected before anybody enters the swimm...

Page 5: ...the handle the pump must always be immersed into the well or water reservoir via a rope Minimum immersion depth during initial operation see 7 TECHNICAL DATA Take care that the pump is located where t...

Page 6: ...ct To clean the suction base and the impeller Fig T1 1 Unscrew the 4 Phillips screws 4 2 Pull the suction base 5 off the pump 3 Clean suction base 5 and impeller 6 the warranty does not become void as...

Page 7: ...500 Max pressure max delivery head bar m 0 5 5 0 0 55 5 5 0 4 4 0 0 5 5 0 Max submersion depth m 6 6 6 6 Min max cut in height cm 23 50 23 50 26 45 26 45 Min max cut out height cm 7 20 7 20 11 16 11 1...

Page 8: ...the purchaser nor a third party has attempted to open or repair the product Only Original GARDENA replacement parts and wear parts have been used for operation Presentation of the receipt Normal wear...

Page 9: ...a erpadla Charakteristiky erpadla Karakteristika rpalka Obilje ja pumpe Karakteristika pumpe Caracteristic pomp Pompa karakter e risi Fuqia e pomp s Pumba karakteristik Siurblio charakteristin kreiv S...

Page 10: ...ke p tager os noget ansvar for skader p vores produkter hvis de p g ldende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brugt originale GARDE...

Page 11: ...jujemo kako ne prihva amo nikakvu odgovornost za o te enja na na im proizvodima nastala uslijed neispravnog popravka od strane servisnog partnera kojeg odobrava GARDENA ili uslijed nekori tenja origin...

Page 12: ...aparelho s a seguir designado s no modelo lan ado por n s no mercado cumpre cumprem os requisitos das diretivas UE harmonizadas as normas de seguran a UE e as normas espec ficas para estes produtos E...

Page 13: ...knis Anbringungsjahr der CE Kennzeichnung Year of CE marking Ann e d apposition du marquage CE Installatiejaar van de CE aanduiding M rknings r CE M rknings r CE merkin kiinnitysvuosi Anno di applicaz...

Page 14: ...Newton Aycliffe County Durham DL5 6UP info gardena husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan...

Reviews: