background image

1. SAFETY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

2. ASSEMBLY   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

3. OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

4. MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

5. STORAGE   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

6. TROUBLESHOOTING   . . . . . . . . . . . . . . . . . . . . . . . .14

7. TECHNICAL DATA  . . . . . . . . . . . . . . . . . . . . . . . . . . .15

8. ACCESSORIES   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

9.  SERVICE / WARRANTY . . . . . . . . . . . . . . . . . . . . . . . .16

Original instructions.

This product may be used under 

supervision, or if instruction 

regarding the safe use of the product has 

been provided and the resulting dangers 

have been understood, by children aged 

8 and above, as well as by persons with 

physical, sensory or mental disabilities or 

a lack of experience and knowledge. Chil-

dren must not be allowed to play with the 

product. Cleaning and user maintenance 

must not be performed by children with-

out supervision. The use of this product by 

young people under the age of 16 is not 

recommended. Never operate the product 

when you are tired, ill or under the influ-

ence of alcohol, drugs or medicine.

Intended use:
The GARDENA Submersible Pump is intended for drain-

age purposes if flooding occurs but also for transferring 

water to and from tanks and pumping them out, for draw-

ing water from wells and shafts, for draining boats and 

yachts and for aerating and circulating water for limited peri-

ods and for pumping chlorinated water in private domestic 

gardens and allotments.

Liquids to be pumped:
The GARDENA Submersible Pump must only be used to 

pump water. 
The pump is fully submersible (water-tight encapsulation) 

and is submerged in water (for max. submersion depth,  

see 7. TECHNICAL DATA). 

The product is suitable for pumping the following liquids:
•   Clear Water Submersible Pump: clean to slightly dirty 

water with a max. particle size of 5 mm.

•   Dirty Water Submersible Pump: dirty water with a 

max. particle size of 25 mm.

The product is not intended for long term use (continuous 

circulation   operation).

  
 

 DANGER! Risk of injury! 

v  

The pump should not be used for the delivery  

of salt water,  corrosive, easily inflammable or 

explosive  liquids (e. g. petrol,  paraffin, thinners), 

oil, heating oil or foodstuffs.

1. SAFETY

IMPORTANT! 

Read the operator’s manual carefully before use  

and keep for future  reference.

Symbols on the product:

 

Read operator’s manual.

General safety warnings
Electrical safety

 DANGER! Electric shock!

 

Risk of injury due to electric current.

v  

The product must be supplied through a residual 

current device (RCD) having a rated residual 

operating current not exceeding 30 mA.

 DANGER! Risk of physical injury!

 

Risk of injury due to electric current.

v

  Disconnect the product from the mains before 

you maintain or replace parts. Thereby the dis-

connected socket must be in the visual range.

Safe operating practices
The water temperature should not exceed 35 °C.
The pump must not be used when people are in the 

water.
Pollution of the liquid could occur due to leakage of 

 lubricants.
Keep bystanders away from the water.
Operate the pump only with the elbow connector.

GARDENA Clear Water Submersible Pump /  

Dirty Water Submersible Pump

EN

11

Summary of Contents for 8600

Page 1: ...8200 Art 9000 8600 Art 9001 9200 Art 9007 10500 Art 9008 EN Operator s Manual Clear Water Submersible Pump Dirty Water Submersible Pump EN...

Page 2: ...A1 2 1 O1 3 A2 y 2 A3 Art 7193 O2 3 A4 Art 7195 y A5 T1 6 5 4 4 3...

Page 3: ...ion and is submerged in water for max submersion depth see 7 TECHNICAL DATA The product is suitable for pumping the following liquids Clear Water Submersible Pump clean to slightly dirty water with a...

Page 4: ...edges Observe the mains voltage The information on the name plate must be in agreement with the data for the mains power grid The pump s mains plug must be disconnected before anybody enters the swimm...

Page 5: ...the handle the pump must always be immersed into the well or water reservoir via a rope Minimum immersion depth during initial operation see 7 TECHNICAL DATA Take care that the pump is located where t...

Page 6: ...ct To clean the suction base and the impeller Fig T1 1 Unscrew the 4 Phillips screws 4 2 Pull the suction base 5 off the pump 3 Clean suction base 5 and impeller 6 the warranty does not become void as...

Page 7: ...500 Max pressure max delivery head bar m 0 5 5 0 0 55 5 5 0 4 4 0 0 5 5 0 Max submersion depth m 6 6 6 6 Min max cut in height cm 23 50 23 50 26 45 26 45 Min max cut out height cm 7 20 7 20 11 16 11 1...

Page 8: ...the purchaser nor a third party has attempted to open or repair the product Only Original GARDENA replacement parts and wear parts have been used for operation Presentation of the receipt Normal wear...

Page 9: ...a erpadla Charakteristiky erpadla Karakteristika rpalka Obilje ja pumpe Karakteristika pumpe Caracteristic pomp Pompa karakter e risi Fuqia e pomp s Pumba karakteristik Siurblio charakteristin kreiv S...

Page 10: ...ke p tager os noget ansvar for skader p vores produkter hvis de p g ldende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brugt originale GARDE...

Page 11: ...jujemo kako ne prihva amo nikakvu odgovornost za o te enja na na im proizvodima nastala uslijed neispravnog popravka od strane servisnog partnera kojeg odobrava GARDENA ili uslijed nekori tenja origin...

Page 12: ...aparelho s a seguir designado s no modelo lan ado por n s no mercado cumpre cumprem os requisitos das diretivas UE harmonizadas as normas de seguran a UE e as normas espec ficas para estes produtos E...

Page 13: ...knis Anbringungsjahr der CE Kennzeichnung Year of CE marking Ann e d apposition du marquage CE Installatiejaar van de CE aanduiding M rknings r CE M rknings r CE merkin kiinnitysvuosi Anno di applicaz...

Page 14: ...Newton Aycliffe County Durham DL5 6UP info gardena husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan...

Reviews: