Circuit breaker
Thermal protection switch: 

In the event of an overload, the pump is switched off by 

the built-in thermal motor protection. After sufficient cool-

ing of the motor, the pump is operational again.

Automatic venting
This pump is equipped with a vent valve which eliminates 

any air pockets in the pump. Depending on the function,  

a small amount of water can escape from the side of the 

housing.

Additional safety warnings
Electrical safety

  

DANGER! Cardiac arrest!

This product makes an electromagnetic field while  

it operates. This field may under some conditions 

interfere with active or passive medical implants.  

To decrease the risk of conditions that can possibly 

injure or kill, we recommend persons with medical 

implants to speak with their physician and the medi-

cal implant manufacturer before you operate the 

product.

Cables
If extension cables are used, these must comply with the 

minimum cross- sections in the table below:

Voltage

Cable length

Cross section

230 – 240 V / 50 Hz

Up to 20 m

1.5 mm

2

230 – 240 V / 50 Hz

20 – 50 m

2.5 mm

2

  

DANGER! Electric shock!

With a cut off mains plug, moisture can get into 

electrical parts via the mains cable and cause 

a short circuit.

v

 Never cut the mains plug off (e. g. to feed through 

wall).

v

 Don’t use the power cable for plugging off.

v

 If the supply cord is damaged, it must be replaced by 

the manufacturer, its service agent or similarly qualified 

persons in order to avoid a hazard.

Mains plug and extension connections must be protected 

from water splashes.
Ensure that the electrical connections for plugs and sock-

ets are made in areas safe from flooding.
Protect the mains plug and the mains power cable from 

heat, oil and sharp edges.
Observe the mains voltage. The information on the name-

plate must be in agreement with the data for the mains 

power grid.
The pump’s mains plug must be disconnected before 

anybody enters the swimming pool or touches the surface 

of the water.
The mains power cable must not be used for fastening or 

transporting the pump. 
For submerging or lifting / securing the pump, please use 

a fastening rope.
Please regularly check the connecting line.
Before using, always subject the pump (especially the 

power cables and the power connections) to a visual 

inspection.
A pump which is damaged should not be used. In the 

event of damage, have the pump checked by GARDENA 

Service.
Assembly instructions: Retighten all screws by hand.
Before use after maintenance, make sure that all parts are 

screwed together.
When using our pumps with a generator, the warnings of 

the generator manufacturer must be observed.

Personal safety

  

DANGER! Risk of suffocation!

Small parts can be easily swallowed. There is also 

a risk that the polybag can suffocate toddlers. Keep 

toddlers away when you assemble the product.
Observe the minimum water level in accordance with the 

characteristics given for the pump.
Allow the pump to run no longer than 10 minutes against 

a closed pressure side.
Sand and other abrasive substances cause increased 

wear and reduce the pump’s output.
The float switch may only be operated outside the water.
The hose must not be disconnected during operation.
Allow the pump to cool down before troubleshooting.
The pump must not be operated without the mounted 

contra-angle handpiece.

2. ASSEMBLY 

  

DANGER! Risk of injury!

 

Injury when the product starts accidentally.

v  

Disconnect the product from the mains before 

you assemble the product.

To screw the elbow connector into the pump  

[ Fig.  A1 ]:

  

 DANGER! Risk of injury!

 

Cut Injury by the impeller.

v

  Operate the pump only with the elbow 

 connector.

EN

12

Summary of Contents for 8600

Page 1: ...8200 Art 9000 8600 Art 9001 9200 Art 9007 10500 Art 9008 EN Operator s Manual Clear Water Submersible Pump Dirty Water Submersible Pump EN...

Page 2: ...A1 2 1 O1 3 A2 y 2 A3 Art 7193 O2 3 A4 Art 7195 y A5 T1 6 5 4 4 3...

Page 3: ...ion and is submerged in water for max submersion depth see 7 TECHNICAL DATA The product is suitable for pumping the following liquids Clear Water Submersible Pump clean to slightly dirty water with a...

Page 4: ...edges Observe the mains voltage The information on the name plate must be in agreement with the data for the mains power grid The pump s mains plug must be disconnected before anybody enters the swimm...

Page 5: ...the handle the pump must always be immersed into the well or water reservoir via a rope Minimum immersion depth during initial operation see 7 TECHNICAL DATA Take care that the pump is located where t...

Page 6: ...ct To clean the suction base and the impeller Fig T1 1 Unscrew the 4 Phillips screws 4 2 Pull the suction base 5 off the pump 3 Clean suction base 5 and impeller 6 the warranty does not become void as...

Page 7: ...500 Max pressure max delivery head bar m 0 5 5 0 0 55 5 5 0 4 4 0 0 5 5 0 Max submersion depth m 6 6 6 6 Min max cut in height cm 23 50 23 50 26 45 26 45 Min max cut out height cm 7 20 7 20 11 16 11 1...

Page 8: ...the purchaser nor a third party has attempted to open or repair the product Only Original GARDENA replacement parts and wear parts have been used for operation Presentation of the receipt Normal wear...

Page 9: ...a erpadla Charakteristiky erpadla Karakteristika rpalka Obilje ja pumpe Karakteristika pumpe Caracteristic pomp Pompa karakter e risi Fuqia e pomp s Pumba karakteristik Siurblio charakteristin kreiv S...

Page 10: ...ke p tager os noget ansvar for skader p vores produkter hvis de p g ldende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brugt originale GARDE...

Page 11: ...jujemo kako ne prihva amo nikakvu odgovornost za o te enja na na im proizvodima nastala uslijed neispravnog popravka od strane servisnog partnera kojeg odobrava GARDENA ili uslijed nekori tenja origin...

Page 12: ...aparelho s a seguir designado s no modelo lan ado por n s no mercado cumpre cumprem os requisitos das diretivas UE harmonizadas as normas de seguran a UE e as normas espec ficas para estes produtos E...

Page 13: ...knis Anbringungsjahr der CE Kennzeichnung Year of CE marking Ann e d apposition du marquage CE Installatiejaar van de CE aanduiding M rknings r CE M rknings r CE merkin kiinnitysvuosi Anno di applicaz...

Page 14: ...Newton Aycliffe County Durham DL5 6UP info gardena husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan...

Reviews: