background image

Cleaning your Garden Pump :

WARNING ! 
Electric shock ! 

Loosening the turbine :

5. Maintenance

GARDENA Garden Pumps are virtually maintenance-free.

After pumping pesticides, lime paints or fertilisers you have to
clean the pump. 

1. Rinse the Garden Pump with lukewarm water (max. 35 °C). 

If necessary add some soft cleaning agent (e.g. washing-up 
liquid). 

2. Remove residuals according to the waste disposal laws 

applicable in your area.

6. Troubleshooting

Risk of injury due to electric shock. 

V

Disconnect Garden Pump from the mains before 
troubleshooting. 

If the turbine clogs due to contamination, it can be loosened.

v

Turn the turbine screw 

8

using a screwdriver. 

Thereby, the clogged turbine is loosened. 

Problem

Probable cause

Remedy 

Pump runs, but the suction 

You didn’t fill the pump with 

v

Fill in liquid (see point 

action doesn’t take place 

any liquid before operation. 

3. Initial Operation). 

The liquid escapes over 

v

Fill up the pump again (see 

the hose which is connected 

point 3. Initial Operation). 

to the delivery side during 

When starting operation hold 

the suction action. 

the pressure hose approx. 1 m 
vertically above the pump, 
until the suction action has 
taken place. 

Leaky or damaged suction 

v

Seal the connections or 

hose. 

check suction hose for 
damages. 

Absolutely vacuum-resistant 
connection is achieved by using 
GARDENA Suction Hoses 
(see point 8. Accessories). 

Leaky screw fitting at the filler 

v

Tighten the screw fitting 

cap 

2

(do not use pliers). 

8

GB

14

Summary of Contents for 4000/4 Inox Multi 3

Page 1: ...uik Beregeningspomp S Bruksanvisning Bevattningspump DK Brugsanvisning Trykpumpe I Istruzioni per l uso Pompa da giardino E Manual de instrucciones Bomba para jard n P Instru es de utiliza o Bomba de...

Page 2: ...g 14 7 After Operation 15 8 Accessories 16 9 Technical Data 16 10 Service Warranty 17 1 Where to Use Your GARDENA Garden Pump GARDENA Garden Pumps have been designed for private use around house and g...

Page 3: ...t be connected via a residual current device Environment v Protect the pump from rain Don t use the pump in wet or moist area Visual check v Before operating the pump first make a visual cheek if ther...

Page 4: ...Tighten the screw fitting 1 of the filler cap 2 by hand do not use pliers The fittings on the input and output side may only be tightened by hand Don t use any hose connection system fittings on the s...

Page 5: ...per missible internal pressure of 6 bar on the delivery side must not be exceeded The to be increased delivery pressure and the pump pressure sum up Example pressure at the water tap 1 5 bar max pres...

Page 6: ...8 using a screwdriver Thereby the clogged turbine is loosened Problem Probable cause Remedy Pump runs but the suction You didn t fill the pump with v Fill in liquid see point action doesn t take plac...

Page 7: ...denly decreases valve e g GARDENA art no 2 977 Suction filter or backflow v Clean filter or back flow preventer clogged preventer Leaks at suction side v Eliminate leak Turbine clogged v Loosen the tu...

Page 8: ...operating pressure With dry running safety GARDENA Prevents the pump from dama Art no 1741 Dry Running Safety ges in case of missing liquid GARDENA For vacuum resistant connection Art no 1729 Bore Hol...

Page 9: ...eping with the requirements of the operating instructions Neither the purchaser or a non authorised third party have attempted to repair the unit The turbine is a wearing part and is not covered by th...

Page 10: ...gegevens in de grafiek zijn gemeten bij een aanzuig hoogte van 0 5 m en bij gebruik van een 25 mm 1 aanzuig slang V rdena ovan r utm tta p en sugh jd av 0 5 m med 25 mm 1 sugslang Tekniske data for de...

Page 11: ...n om skadan beror p att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra n Original GARDENA reservdelar har anv nts Samma sak g ller f r kompletteringsdelar och tillbeh r...

Page 12: ...igheid S EU Tillverkarintyg Undertecknad firma GARDENA Manufacturing GmbH Hans Lorenser Str 40 D 89079 Ulm intygar h rmed att nedan n mnda produkter verensst mmer med EU s direktiv EU s s kerhetsstand...

Page 13: ...bH Hans Lorenser Stra e 40 D 89079 Ulm vakuuttaa ett allamainitut laitteet t ytt v t tehtaaltamme l h tiess n yhdenmukaistettujen EY direktiivien EY turvallisuusstandardien ja tuotekohtaisten standard...

Page 14: ...Phone 36 80 20 40 33 gardena gardena hu Iceland Johnson Kaaber Tunguhalsi 1 110 Reykjavik ooj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p...

Reviews: