RC1xx LED Lighting Controllers - User Manual
—
34
—
When Ethernet messages are enabled, any error reports are sent to
the most recent UDP or TCP/IP address from which a command has
been received. These messages take the form:
Evtc,e
Where:
c
= 1 for events concerning the light output, otherwise 0
e
= the event value (see Section 11.3, “Event codes”)
Clear any errors
Use this command to read the last event or error code when Ethernet
messaging has been disabled:
GR
Any error displayed on the RC120 is cleared. If this was a lighting
error, the unit resumes auto-sensing. If there are no outstanding
events or errors, the ‘
>
’ prompt is returned.
Set/Clear the webpage password
This command sets the web page password. Up to six characters can
be chosen. Type in:
EYasc1,asc2,asc3,asc4,asc5,asc6
Where:
asc1
to
asc6
are decimal ASCII values for the letters of your
password
For example, a value of 65 is ‘A’, 66 is ‘B’ and so on up to 90 for ‘Z’.
Note:
When you use this password to access the RC120 through
the web page, you must use the actual characters and not the ASCII
values. Use upper case characters and do not enter commas or
spaces.
Disable the keypad
You may find it necessary to lock the front panel keypad to prevent
any unauthorised changes to the settings to the RC120. To disable
the keypad, type in the following command:
KBd,c
Where:
d
= 0 to enable the keypad.
d
= 1 to disable the keypad, but allow the unlock code to be
entered on the keypad.