RC1xx LED Lighting Controllers - User Manual
—
26
—
dEL
is displayed. Press the
SEL
button
to set up the pulse delay time (refer to
Section 10.2.6 “Setting time periods”).
Press the
SEL
button to confirm the period
set.
PUL
is displayed. Press the
SEL
button to
set up the pulse width (refer to Section
10.2.6 “Setting time periods”). Press the
SEL
button to confirm the period set.
rEt
is displayed. Press the
SEL
button to
set up the re-trigger time (refer to Section
10.2.6 “Setting time periods”). Press the
SEL
button to confirm the period set.
Use the
and
buttons to set the
Trigger flag:
F P
is enabled,
F-P
is disabled.
Press the
SEL
button.
Use the
and
buttons to set the Error
Detect flag:
F E
is enabled,
F-E
is disabled.
Press the
SEL
button.
Pulsed operation is set up.
Note:
If you set the brightness to more than 100%, the pulse width is
limited to a safe value as described in Section 7, “General description”.
10.2.6 Setting time periods
When the RC1xx requires you to enter a numeric value, the right hand digit
flashes to indicate you can use the
and
keys to change the value.
To set pulse delay, re-trigger and pulse width values a scheme is used
where the exponent (power of ten) of the value is set. The exponent values
are as follows:
Exponent
value
Number
format
Range of values
E-2
9.99
Values are displayed in seconds from 10ms
to 5 seconds in steps of 10ms.
E-3
999.
Values are displayed in milliseconds from
1ms to 999 ms in steps of 1ms.
E-4
99.9
Values are displayed in milliseconds from
0.1ms to 99.9 ms in steps of 0.1ms.