23
DISPLAY : MONITOR
SEQUENCE DWELL
: The time that each screen is displayed in a sequence operation.
SPOT-OUT DWELL
: The time that each screen is displayed on the spot monitor outputs.
DE-INTERLACE MODE
: When recording any channels in D1 resolution (704 x
480
) this should be set to
ON to
prevent motion distortion during playback.
ALARM POP-UP MODE
: When set to ON, an alarm input will cause the associated channel to display
full screen.
ALARM POP-UP DWELL
: Determines how long the full screen popup is displayed after an alarm input.
If the alarm condition continues, the popup screen is displayed constantly.
MOTION POP-UP MODE
: When set to ON, motion detection will cause the associated channel to display
full screen.
MOTION POP-UP DWELL
: Determines how long the full screen popup is displayed after motion detection.
If motion continues, the popup screen is displayed constantly.
DISPLAY MODE
: The DVR output can be optimized for display on a VGA or AV (CRT) monitor.
To change any of these settings, highlight MONITOR and press
ENTER
to select.
Use the
CURSOR KEYS
to navigate to the option required. Press
ENTER
to select the option (the cursor
changes
to yellow
) and use the
CURSOR KEYS
to change the setting. Press
APPLY
to save the setting
or
PREVIOUS
to cancel.
Note: When changing between display modes, you must shutdown and restart the DVR before
any changes will take effect.
SYSTEM SETUP
SYSTEM SETUP
Click the
MONITOR
menu. Click on a field to
change its setting.
Then click the button to toggle the setting.