Technical data
G&D DP1.2-Vision-Fiber ·
68
English
Features of transmission modules
MULTIMODE TRANSMISSION MODULE
Data transmission
Type:
Optical fibres (2 fibres)
Type of interface:
LC duplex
Cable length (max.)
Multimode 62.5/125
μ
m:
100 meters
Multimode 50.0/125
μ
m,
Class OM2:
200 meters
Multimode 50.0/125
μ
m,
Class OM3:
400 meters
Performance data
Wavelength(
λ
):
850 nm (830 nm bis 860 nm)
Optical power output (P
OUT
)
in 50 oder 62,5
μ
m MMF:
-9,0 dBm bis -2,5 dBm
Receiving sensitivity (P
MIN
):
-15 dBm (OMA)
Sensitivity – Stressed (P
S
):
138
μ
W (50
μ
m MMF)
SINGLEMODE (S) TRANSMISSION MODULE
Data transmission
Type:
Optical fibres (2 fibres)
Type of interface:
LC duplex
Cable length (max.)
Singlemode 9/125
μ
m,
Class OS1:
5 Kilometer
Performance data
Wavelength(
λ
):
1310 nm (1260 nm bis 1350 nm)
Optical power output (P
OUT
)
in 9
μ
m SMF:
-9,5 dBm bis -3,0 dBm
Receiving sensitivity (P
MIN
):
-18 dBm (OMA)
SINGLEMODE (S+) TRANSMISSION MODULE
Data transmission
Type:
Optical fibres (2 fibres)
Type of interface:
LC duplex
Cable length (max.)
Singlemode 9/125
μ
m,
Class OS1:
10 Kilometer
Performance data
Wavelength(
λ
):
1310 nm (1260 nm bis 1360 nm)
Optical power output (P
OUT
)
in 9
μ
m SMF:
-8,4 dBm bis -1,0 dBm
Receiving sensitivity (P
MIN
):
-18 dBm (OMA)